LRX
VULTURE
Check for the latest manual updates at www.lrx-lighting.com
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE
10
10
The LRX Vulture has a dual power system. Batteries may be used to
manouver and program the unit into position for assembly and
dissasembly. The unit will shutdown in aproximately 6 minutes
where there is no AC power.
The unit will maintain the last power setting when mains power is
restored. For example if the unit was left on when the battery shut off
– or AC was lost, it will power up again when AC is restored.
If the Vulture shuts off (battery), it may be turned back on until the
battery is exhausted. This would be several hours of intermitant use.
IMPORTANT:
The Tilt Axis is capable of providing in excess of 100ft.lbs before the
current limit activates. When the motor is deactivated, the unit has a
holding force of 30 ft.lbs. If an unbalanced load exceeding 25 ft.lbs is
anticipated, then counterweight is required to prevent the load from
slowly drooping.
Home Button Usage:
1) Escape from menu options.
2) Hold to automatically
position the unit for transport
POWER:
ON/OFF toggle
EMERGENCY STOP:
Press in an emergency