The control unit is fitted with an LED for every low voltage
command input so that the status may be monitored
immediately.
Operation principle: LED on = input closed, LED off = input
open.
N
OTES FOR THE
I
NSTALLER
The control unit was designed for installation with other
components (motor, gate, safety devices) in order to form a
finished product (machine) in compliance with the Machines
Directive.
The safety of the final installation site and adherence to all
current legislation is the responsibility of the individual
assembling the various parts to construct a complete closure
device.
We advise that you also take note of the following
recommendations:
Before shutter automation, it is necessary to check the
product is in good condition and that it complies with EN
12604 and the Machines Directive.
The wiring of external electrical components must comply
with EN 60204-1 as amended in section 5.2.7 of EN
12453. Power supply leads and connection cables must
be secured through the use of cable clamps, which are
supplied with the product.
The motor reducer used to move the shutter must comply
with section 5.2.7. of EN 12453.
If present, the keypad for manual control must be
mounted in such a way that the user is not placed in a
dangerous situation, in compliance with point 5.2.8 of EN
12453.
The control unit is not equipped with a 230 V a/c electric
line sectioning device. The installer is responsible for
installing a sectioning device in the system. An
omnipolar switch with overheating category III must be
installed. The sectioning device must be positioned so
that it is protected against accidental closure, in
compliance with section 5.2.9 of standard EN 12453.
In compliance with section 5.4.2 of EN 12453 it is
recommended that motor reducers fitted with an
electromechanical unlocking device are used, so that the
shutter can be moved manually if necessary.
In compliance with section 5.4.3 of EN 12453,
electromechanical unlocking systems or similar devices
should be used as these enable the shutter to stop
safely at its stop limit.
Power supply and motor connection cables which are
suitable for use in conjunction with the pg9 cable clamps
provided must have an external diameter with a
measurement between 4.5 and 7 mm. The internal
conductor wires must have a nominal cross-section of
0.75 mm². If a channel is not used, we recommend that
cables in H05RR-F material are used.
Once installation is complete, all the checks listed in EN
12453
– EN 12445 must be performed so as to ensure
that closure occurs in compliance with all stipulations.
For the radio receiver to operate correctly when two or
more control units are used, we recommend that you
install the devices at least 3 metres away from each
other.
F
OR THE
U
SER
- I
MPORTANT
-
The device should not be used by children or by individuals
with reduced physical or psychological abilities unless
supervision is provided or instruction given on how to operate
it.
- Do not let children play with the device; keep radio controls
out of their reach.
- CAUTION: Keep this instruction manual in a safe place and
adhere to the important safety instructions contained within it.
Non-adherence to these instructions may lead to property
damage and serious accidents.
- Examine the system frequently to check for any signs of
damage. Do not use the device if it needs to be repaired.
Warning
All operations which require the casing to be opened (such as
wire connection, programming, etc.) must be carried out during
installation, by skilled staff only.
For any other procedure which requires the casing to be
opened again (programming, repairs or site modifications),
please contact the technical assistance service.