LRX™ FRESNEL
Check for the latest manual updates at www.lrx-lighting.com
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE
20
20
fixture and perform a visual inspection and check continuity. We have
seen lamps that look OK, but the feed wire is broken inside near the
base.
Check socket contacts and wiring.
METAL HALIDE MODE LAMP NOT IGNITING
Please store ballast in warm dry location when not in use.
Damp ballasts are the number one cause of lamps not operating, damp
ballast will need to be placed in a warm dry location and allowed to dry
before attempting to use.
Also check for signs of water in head cable connectors, dry as required.
Check that the lamp access door is closed and door interlock switch is
operating.
Check head extension cables and panel mount connector pins (paying
particular attention to the small pins are not dislodged or damaged
which would cause improper contact.
Install lamp ensure is properly seated
(ceramic against ceramic and the
contact tee bolt clamp is tight).
Test with a ballast (ensure output matches lamp wattage) and a head
extension cable that are known to be good.
Ensure line voltage to ballast input is above 205 VAC when under load.
Check socket contacts and wiring to socket. Check for signs of
overheating contacts or arcing.
METAL HALIDE LAMP RUNS AND
SHUTS OFF AFTER TEN OF MORE MINUTES
The lamp could be near the end of its life
Check that the lamp access door is properly closed and that interlock
switch is positively engaged.
Check that voltage at the fixture or ballast, long cable runs can
significantly reduce voltage, thus decreasing performance.
Check lamps, socket contacts and wiring.
Unsure about anything or questions? Contact representative before use.
For the latest version of this manual please visit “lrx-lighting.com”