LPT-3000 Remote User
’
s Guide
44
LP Technologies Tech Support
E-mail
, or Call
316-831-9696 Ext 0
[Figure 7-1] Delta Marker Function
2. Utilization of RBW ; Distinction of a Small Signal
To distinguish between two signals of similar frequencies, it is required to consider configuration
characteristics and 3dB bandwidth of the analyzer IF (RBW) filter. The configuration characteristics of
the filter are defined by selectivity, the ratio of the 3dB and the 60dB bandwidths. If a small signal is
located too close to a large signal, the small signal may become blocked by IF (RBW) filter selection.
- Example of Use (IF (RBW) Selection)
Characteristics and measuring method of IF (RBW) can be obtained by measuring two input signals with
a frequency difference of 200 kHz and an amplitude difference.
⒜
Connect the spectrum analyzer as shown in Figure 7-2 to obtain a signal with a frequency
difference of 200kHz. Set the first signal generator as 100MHz and -30dBm.