LPT-3000 Remote User
’
s Guide
39
LP Technologies Tech Support
E-mail
, or Call
316-831-9696 Ext 0
only for Mark1.
- Ref Off/On
This button is used to turn ON or OFF internal 80 MHz standard signal. When Ref is ON, the LPT-3000R
will not display any RF input signal connected to it. This function is used mainly for unit testing purposes.
- Align
This button is used to re-calibrate the LPT-3000R spectrum analyzer for increased accuracy.
- Autoset
The Autoset function searches for the RF signal and automatically sets the parameter.
- Channel Power
This function measures Channel Power and Power Spectrum Density within a selected channel
bandwidth.
- DTV MASK
This function measures the Shoulder Attenuation used for digital TV measurement.
-Trace
This function Allows the user to display a trace in Max, Min, Pause and Live mode at a time or
simultaneously. Operators can also pause a trace by selecting “View”
.
-Status Hold
This tool allows users to hide all controls and display only the trace.
To release the controls, the default password is “0000” or you can simply close the session and
reconnect.