background image

LP Morgan Installation Instructions  | 11

LP Morgan Resi-Lift Manual

Warranty information

Keep your original receipt for warranty.

Please fill out the online warranty form in order to qualify for the manufacturer’s warranty.

http://www.lpmorgan.com.au/owners.html

The  warranty  covers  defects  in  workmanship  and  materials,  provided  this  product 
has been installed in a normal environment and maintained according to the written 
instructions. Herma warrants the product against loss of usefulness, discolouration or 
deterioration of optical quality within the warranty period as a result of manufacturing or 
material defects. This warranty applies only within Australia.

Please return your goods to the place of purchase for all warranty claims.

Conditions  

Any equipment replaced pursuant to the terms of this warranty shall be retained 
by Herma.
All  costs  related  to  de-installation  and  re-installation  of  the  product  covered  by  this 
warranty are not the responsibility of Herma Technologies. Herma will not be responsible 
for any consequential damages during or following installation procedures.
Herma  is  not  responsible  for  any  freight  costs  relating  to  repair  or  replacement.  
Equipment  must  be  returned  to  Herma  in  suitable  packing  to  prevent  damage  in 
transit. Herma will not accept any responsibility for damage to the equipment caused 
by inadequate or unsuitable packing, or for any damage howsoever caused whilst the 
goods are in transit.
Herma  Technologies  shall  not  be  liable  for  any  injury,  loss  or  damage,  direct  or 
consequential, arising out of the use of, misuse of, or inability to use, the equipment.
This  Warranty  does  not  cover  any  product  which  has  been  subjected  to  misuse, 
abuse, neglect, accidental or intentional damage, improper voltage or any alteration 
which affects the reliability or performance of the equipment not attributable to faulty 
manufacture, parts or labour and without limiting the generality of the foregoing.

This  Warranty  does  not  cover  any  product    where  usage,  adaptation  or  installation  
are not in accordance with our written installation and operating instructions. 

Warranty Period:

One year from date of purchase.

Summary of Contents for Resi-Lift

Page 1: ...www lpmorgan com au LP Morgan Resi Lift manual...

Page 2: ...e allowed to rest on ceiling closure during operation Entire bottom of unit must be unobstructed to permit proper operation Unit must be installed level use a carpenter s level Unit operates on 220V A...

Page 3: ...Based on screen location and projector specifications determine proper position for projector installation Confirm that there is adequate space for installation and operation Minimum clearance above c...

Page 4: ...r field connections is located inside the unit on the left as seen from front or non scissored end Unit is shipped with internal wiring complete to the terminal strip Once the unit has been lowered tu...

Page 5: ...electrical connections before proceeding Cycle unit down and up several times to confirm satisfactory operation 220V Single Station Control CE Approved 3 position UP OFF DOWN switch permits operation...

Page 6: ...l new holes Control cables maximum of four should be laced through our Cable Management System back scissor only This will ensure that cords do not become tangled and damaged during Micro Projector Li...

Page 7: ...ill stop working until it has cooled to a safe temperature before it will start operating again Please refer to diagram below for these instructions Limit switches for the Resi Lift are preset at the...

Page 8: ...at the factory LP Morgan does not recommend changing this position using the limit switch The up position of the closure may be changed by changing the length of threaded rod see instructions for clo...

Page 9: ...o diagram below for these instructions Manual Installation Notes When the Resi Lift is in the closed position determine the spacing from the plate to the faceplate to allow for fitting of the projecto...

Page 10: ...Down Dashed wiring by electrician Control switch To 220v 50 Hz Blue Common Black Up N DN UP Neutral L1 Wiring diagrams Single Station Control CE Approved important If you are operating this unit with...

Page 11: ...ma Technologies Herma will not be responsible for any consequential damages during or following installation procedures Herma is not responsible for any freight costs relating to repair or replacement...

Page 12: ...chment instructions Allow for 15mm between cable and end of scissor when lift is fully down Use a 15mm diameter object such as a pin to measure See Note 8 See Note 11 Cable Caution Improper installati...

Page 13: ...on LP Morgan recommends a limit of four cables in addition to the pre wired power cord 220V lifts do not come with with pre wired power cord PLEASE NOTE The cable installer is responsible for ensuring...

Page 14: ...r September 2012 Version 1 2 Information in this document is subject to change without notice Herma Technologies All rights reserved This document is protected against unauthorised copying electronic...

Reviews: