10L Dehumidifier

For Customer Services & Spare Parts please call 0345 209 7461

Opening times: Monday - Friday 8am – 8pm & Saturday 9am – 1pm

Or visit us at www.productcare.co.uk

PLEASE RETAIN

FOR FUTURE REFERENCE

Model Number: LDH1001

220-240V AC 50/60Hz 290W

Summary of Contents for LDH1001

Page 1: ...tomer Services Spare Parts please call 0345 209 7461 Opening times Monday Friday 8am 8pm Saturday 9am 1pm Or visit us at www productcare co uk PLEASE RETAIN FOR FUTURE REFERENCE Model Number LDH1001 2...

Page 2: ...12 Emptying your Dehumidifier 13 Cleaning and Care 14 15 Troubleshooting 16 Guarantee and Customer Services 17 Spare Parts 18 Connection to the Mains Supply 19 Notes 20 Specification 21 CONTENTS For...

Page 3: ...daptors or extension leads when connecting the appliance to the electrical power supply Do not plug in if the plug is damaged Do not pull twist or damage the power cable Do not plug in or un plug the...

Page 4: ...designed to operate on 220 240V AC 50Hz Connection to any other power source may damage the unit This product may be fitted with a non re wireable plug If it is necessary to change the fuse in the plu...

Page 5: ...ning times Monday Friday 8am 8pm Saturday 9am 1pm Or visit us at www productcare co uk x 1 Control panel 2 Air intake grille 3 Water drawer 4 Air filter behind the air intake grille 1 2 3 4 5 6 7 8 5...

Page 6: ...0345 209 7461 Opening times Monday Friday 8am 8pm Saturday 9am 1pm Or visit us at www productcare co uk 1 Power 2 Silent Mode 3 Water Drawer Full Indicator 4 Display 5 Up Down Control Pads 6 Auto Defr...

Page 7: ...for good air circulation Allow at least 40cm of air space above the unit for good air circulation Place the unit in an area where the temperature will not fall below 5 C 41 F The coils can become cove...

Page 8: ...ay shows the actual room humidity level within 5 accuracy The humidity level can be set using the instructions for Setting the Humidity Continuous Extraction Mode For maximum extraction rate the Conti...

Page 9: ...the Humidity The desired humidity level can be set within a range of 35 to 85 Relative Humidity in 5 increments by pressing the and keys To select the desired humidity level ensure the unit is not on...

Page 10: ...tton and the display will flash 0 0 Use the up and down controls to select the desired delayed start The delayed start time can be adjusted in 0 5 hour increments up to 10 hours and then in 1 hour inc...

Page 11: ...removed When the water drawer is not replaced in the proper position 3 Minute Restart After the unit has stopped it cannot be restarted for 3 minutes This is to protect the unit Operation will automat...

Page 12: ...ug the unit and plug it back in If error repeats call customer service ES Tube Temperature sensor error Unplug the unit and plug it back in If error repeats call customer service EC Refrigerant leakag...

Page 13: ...machine will restart operation after 3 minutes Continuous Draining Water can be automatically emptied into a floor drain by attaching the unit with a 12mm hose Remove the rubber bung from the Drain Ho...

Page 14: ...Grip the tab on the filter and pull the filter downwards Clean the filter with warm soapy water Rinse and let the filter dry before replacing it Do not clean the filter in a dishwasher To Replace the...

Page 15: ...few weeks clean the drawer to prevent growth of mould mildew and bacteria Partially fill the drawer with clean water and add a little mild detergent Swish it around in the drawer empty and rinse NOTE...

Page 16: ...w enough Check that all doors windows and other openings are securely closed Room temperature is too low below 5 C 41 F There is a kerosene heater or something giving off water vapour in the room The...

Page 17: ...the discretion of the retailer The following conditions apply The product must be returned to the retailer with the original proof of purchase The product must be installed and used in accordance wit...

Page 18: ...g times Monday Friday 8am 8pm Saturday 9am 1pm Or visit us at www productcare co uk To check the availability of the following spare parts simply contact our friendly Customer Services team using the...

Page 19: ...end of a screwdriver into the recess in the fuse holder of the plug 2 Pull the fuse holder upwards until free of the plug and slide the fuse out 3 Replace the fuse and replace fuse holder pushing down...

Page 20: ...NOTES Page 20...

Page 21: ...n Page 21 Model LDH1001 Voltage 220 240V 50Hz Power Input 290W Moisture Removal 10L day DB 300C RH80 Refrigerant R134a 80g Overall Size D x W x H 24 7cm 30 8cm 45 6cm Operating Temperature 50C 350C We...

Page 22: ...ling of materials contained within Your co operation is vital to ensure the success of these schemes and for the protection of the environment For your nearest disposal facility visit www recycle more...