109
1. Press
MENU| MENU
, use
↓
↑
to select
NMEA
2000
and press
ENT
.
2. Highlight
B
US
S
ETUP
and press
ENT
, which will open the Bus Configu-
ration menu. A list of network devices will be at the top of the page.
3. Select the desired EP-15 Fluid Level and press
ENT
.
4. Press
↓
to select
C
ALIBRATE
and press
ENT
. The Device Calibration
menu will appear.
5. Highlight
N
UM
P
TS
, press
ENT
and select
5
. Press
ENT
.
6.
Make sure your tank is empty, then
highlight
F
LUID
L
EVEL
and press
ENT
.
Select
E
MPTY LEVEL
and press
ENT
.
7.
Select
C
ALIBRATE
and press
ENT
. The following message will appear:
Empty Level Calibration Completed
. Press
ENT
.
8.
Add 1 quarter tank of fuel, highlight
F
LUID
L
EVEL
and press
ENT
.
Select
1
Q
TR
L
EVEL
and press
ENT
.
9.
Select
C
ALIBRATE
and press
ENT
. The following message will appear:
1
Qtr Level Calibration Completed
. Press
ENT
.
10. Add another quarter tank of fuel, which should raise the fuel level
to half a tank. Highlight
F
LUID
L
EVEL
and press
ENT
.
Select
H
ALF LEVEL
and
press
ENT
.
11.
Highlight
C
ALIBRATE
and press
ENT
. The following message will ap-
pear:
Half Level Calibration Completed
. Press
ENT
.
12. Add another quarter tank of fuel, which should raise the fuel level
to 3 quarters of a tank. Highlight
F
LUID
L
EVEL
and press
ENT
.
Select
3
Q
TR
L
EVEL
and press
ENT
.
13.
Select
C
ALIBRATE
and press
ENT
. The following message will appear:
3
Qtr Level Calibration Completed
. Press
ENT
.
14. Top off the tank, highlight
F
LUID
L
EVEL
and press
ENT
.
Select
F
ULL
L
EVEL
and press
ENT
.
15.
Select
C
ALIBRATE
and press
ENT
. The following message will appear:
Full Level Calibration Completed
. Press
ENT
, then press
EXIT
repeat-
edly to get back to the main display.
Fuel Flow Calibration in a Suzuki Engine Interface
The default calibration for the Suzuki Engine Interface is adequate in
most cases, but if Fuel Used readings are off by more than 3 percent,
calibration is recommended.
To check engine interface accuracy:
Select Fuel Used to be shown as Overlay Data on your unit's main dis-
play. Refer to the Overlay Data segment of this manual for instructions
on how to select Fuel Used data as Overlay Data.
www.Busse-Yachtshop.de email: [email protected]
Summary of Contents for X510C
Page 12: ...6 Notes www Busse Yachtshop de email info busse yachtshop de...
Page 94: ...88 Notes www Busse Yachtshop de email info busse yachtshop de...
Page 122: ...116 Notes www Busse Yachtshop de email info busse yachtshop de...
Page 123: ...117 Notes www Busse Yachtshop de email info busse yachtshop de...
Page 124: ...118 Notes www Busse Yachtshop de email info busse yachtshop de...