Calibrate
Calibration may be required to accurately match measured flow
with actual fuel flow. Access calibration from the Refuel dialog.
Calibration is only possible on Navico’s Fuel Flow sensor.
1.
Start with a full tank and run the engine as it would normally be
operated.
2.
After at least several liters (a few gallons) have been used, the
tank should be fully refilled, and the Set to full option selected.
3.
Select the Calibrate option.
4.
Set the actual amount used based on amount of fuel added to
the tank.
5.
Select OK to save settings. The Fuel K-Value should now show a
new value.
Ú
Note:
To calibrate multiple engines repeat the steps above, one
engine at a time. Alternatively, run all engines simultaneously,
and divide the Actual amount used by the number of engines.
This assumes reasonably even fuel consumption on all engines.
Ú
Note:
The Calibrate option is only available when Set to full is
selected, and a Fuel Flow is connected and set up as a source.
Ú
Note:
A maximum of 8 engines is supported using Fuel Flow
sensors.
Fuel Level
With the use of a Navico Fluid Level device connected to a suitable
tank level sensor, it is possible to measure the amount of fuel
remaining in any equipped tank. The number of tanks must be set
in Vessel Setup dialog, initiated from the Fuel setting options page,
to allow discrete tank assignment of the Fluid Level devices.
Select Device list on the Network page, and view the Device
Configuration dialog for each sensor, and set the Tank location,
Fluid type, and Tank size.
For setting up the Instrument bar or a gauge on the Instrument
page with Fluid Level device data, refer to the Operator Manual.
Ú
Note:
A maximum of 5 tanks is supported using Fluid Level
devices.