Lowara FHE SERIES Instructions For Installation And Use Manual Download Page 7

22

en

During operation, the outer surface of the pump (if hot liquids are being pumped) and

the outer surface of the motor can exceed 40°C. Do not touch with parts of your body
(e.g.: hands) and do not put combustible material into contact with the pump.

7. Maintenance

Maintenance operations must be performed by skilled and qualified personnel only. Use suitable

equipment and protection devices. Observe the accident prevention regulations in force. If you
need to drain the pump, make sure that the drained liquid does not cause damage or injuries.

The pump does not need any ordinary scheduled maintenance.
It may require maintenance in special cases, generally consisting of cleaning the impeller and replacing
the mechanical seal.

Before performing any pump maintenance make sure the motor is disconnected from the mains.

The reference number of each individual component can be found in the exploded views at pages 104÷118.
The motor, bracket, impeller and all the parts mounted on the shaft can be disassembled without discon-
necting the pump body from the system.

Remove the drain plug and drain the pump body, then proceed as follows:

7.1 FHE - 2FHE disassembly

- FHE: Remove the screws that secure the adapter (4) to the pump body (1); remove the motor (9)/adap-

ter/mechanical seal housing (3) and impeller assembly (2) from the pump body; remove the O-ring (6)
and the stationary part of the mechanical seal (7).
At this point both the motor and the liquid end are accessible for maintenance and cleaning.

- 2FHE: Loosen the fastening screws that secure the suction flange (4) to the pump body (1), recover

the O-ring (8) from the pump body, slide out impeller A (2), remove the diffuser (3), slide out impeller B
(2A) and the rotating assembly of the mechanical seal (7), then recover the fixed assembly of the me-
chanical seal (7) from the pump body. At this point both the motor and the liquid end are accessible for
maintenance and cleaning operations.

7.2 FHS disassembly

Proceed as indicated in paragraph 7.1 but remove the motor/pump support as well.
Please note that the impeller is keyed to the stub shaft fixed directly on the motor shaft extension.

7.3 SHE-SHS-SHOE-SHOS-SHOD  disassembly

Version with support:

Support the motor using the special hooks and ropes or shims. Loosen all the screws that fasten the
pump body (1) to the adapter (4), and move the motor back until the shaft extension and the impeller (2)
are extracted from the pump body. At this point both the motor and the liquid end are accessible for
maintenance and cleaning.

Version with supports on the motor housing

Loosen the screws that fasten the pump casing (1) to the adapter (4) and the screws that fasten the
motor feet to the base. Then proceed as described for the version with bracket: move the motor back
until the shaft extension and the impeller are extracted from the pump body. At this point both the motor
and the liquid end are accessible for maintenance and cleaning. See the component list for the names
and ordering codes of spare parts.

7.4 Assembly procedure

For re-assembly, follow the disassembly procedures in the reverse order. Change the gaskets and any
damaged or worn parts.

Summary of Contents for FHE SERIES

Page 1: ...RIE FHE FHS SHE SHS SHO Instru es instala o euso pt MONOBLOK CENTRIFUGALE ELEKTROPOMPEN SERIE FHE FHS SHE SHS SHO Aanwijzingen voor de installatie en het gebruik nl HELST BTE CENTRIFUGALELEKTROPUMPER...

Page 2: ...L INSTALLATION ET L EMPLOI 1 G n ralit s page24 2 Contr le pr liminaire 24 3 Utilisations 24 4 Limites d utilisation 24 5 Installation 24 6 Fonctionnement 26 7 Entretien 27 8 Recherche des pannes 29 9...

Page 3: ...correspondante suivant les sp cifications suivantes D CHARGES LECTRIQUES Avertit que la non observation de la prescription comporte un risque de choc lectrique DANGER Avertit que la non observation d...

Page 4: ...and SHOD series of pumps are suitable for pumping liquids containing solid substances mea suring up to 60 of the diameter of the discharge port 4 Working limits The pump is not suitable for dangerous...

Page 5: ...the delivery pipe or a recirculation bypass between the delivery side and the supply tank FIGURE 1 Correct installation A Eccentric reductions B Positive gradient C Good immersion D Large bends E Suc...

Page 6: ...to be pumped To fill the pump remove the fill plug and proceed as follows Pump with positive suction head open the suction gate valve and let the liquid in until it comes out of the fill plug Pump wi...

Page 7: ...ntenance and cleaning 2FHE Loosen the fastening screws that secure the suction flange 4 to the pump body 1 recover the O ring 8 from the pump body slide out impeller A 2 remove the diffuser 3 slide ou...

Page 8: ...tting D The pump s delivery is higher than the rated one E Dense and viscous liquid A Supply electrical power B1 Replace fuses with adequate ones B2 Repair the motor or replace the cable C Reset the p...

Page 9: ...102 FIG ABB KUWA EIK EK L P C RYS 4 FIG ABB KUWA EIK EK L P C RYS 3 1 3...

Page 10: ...s of the spare parts correspond to the ones in our specific catalog Les num ros de r f rence susdits correspondent aux num ros de notre catalogue pi ces de rechange Die Ersatzteil Nummern entsprechen...

Page 11: ...FHE FHE4 Serie Series S rie Baureihe Sarja Serisi Cep Seria 104...

Page 12: ...ring OR O Ring OR Uszczelka O Ring 9 Motore completo Complete motor Moteur complet Kompletter Motor Motor completo Motor complete Complete motor Komplet motor Komplett motor T ydellinen moottori Moto...

Page 13: ...FHS FHS4 Serie Series S rie Baureihe Sarja Serisi Cep Seria 106...

Page 14: ...ior Achterste schraapring Afstandsstykke bagest Bakre mellanl gg Takav lilevy Distanseskive bak Arka ara halkas Wyg adzanie tylne 7 Tenuta meccanica e guarnizione OR Mechanical seal and O Ring Garnitu...

Page 15: ...2FHE 2FHE4 Serie Series S rie Baureihe Sarja Serisi Cep Seria 108...

Page 16: ...ve O Ring OR Uszczelnienie mechaniczne i uszczelka O Ring 8 Guarnizione OR O Ring Joint torique O Ring Aro t rico Veda o OR O ringafdichting O ring O ring O rengas O ring OR O Ring OR Uszczelka O Rin...

Page 17: ...SHE SHE4 Serie Series S rie Baureihe Sarja Serisi Cep Seria 110...

Page 18: ...g OR Mekanik conta ve O Ring OR Uszczelnienie mechaniczne i uszczelka O Ring 8 Guarnizione OR O Ring Joint torique O Ring Aro t rico Veda o OR O ringafdichting O ring O ring O ren gas O ring OR O Ring...

Page 19: ...SHS SHS4 Serie Series S rie Baureihe Sarja Serisi Cep Seria 112...

Page 20: ...ccanica e guarnizione OR Mechanical seal and O Ring Garniture m canique et joint torique Gleitringdich tung und O Ring Ret n mec nico y aro t rico Vedante mec nico e veda o OR Mechanische asafdichting...

Page 21: ...SHOE SHOE4 Serie Series S rie Baureihe Sarja Serisi Cep Seria 114...

Page 22: ...les taille 71 Kompletter Motor nur 4polig Gr e 71 Motor completo s lo 4 polos tama o 71 Motor complete s 4 p los grandeza 71 Complete motor alleen 4 polig grootte 71 Samling med s t til fastg relse af...

Page 23: ...SHOS SHOS4 Serie Series S rie Baureihe Sarja Serisi Cep Seria 116...

Page 24: ...as O ring OR O Ring OR Uszczelka O Ring 9 Motore completo Complete motor Moteur complet Kompletter Motor Motor completo Motor complete Complete motor Komplet motor Komplett motor T ydellinen moottori...

Page 25: ...SHOD SHOD4 Serie Series S rie Baureihe Sarja Serisi Cep Seria 118...

Page 26: ...i es OR Set O dichtingsringen O ringe Sats med O ringar O rengassarja Sett med O ringer OR O Ring kiti OR Zestaw uszczelnie mechanicznych i uszcze lek OR 9 Motore completo Complete motor Moteur comple...

Page 27: ...127...

Page 28: ...iguse teha muudatusi eelnevalt ette teatamata lv Lowara patur ties bas veikt izmai as bez iepriek ja br din juma lt Lowara pasilieka teis atlikti pakeitimus be i ankstinio sp jimo pl Lowara zastrzega...

Reviews: