background image

I5

8

0

 G

B

 P

L

 0

8

 2

0

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

3

1

1

0

0

4

1

9

2

G

B

CONTENTS

Page

Introduction   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2

Description  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2

Front status LEDs  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

3

IR programming port  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

3

Parameter setting from PC   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

3

Parameter setting from smartphone or tablet with CX 02 Wi-Fi dongle  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

3

Parameter setting from smartphone or tablet with NFC  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

3

Parameter table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4

Alarms  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

5

Description of the alarms  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

5

Programmable inputs default settings  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

5

Installation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

5

Recommendations  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

6

Connection diagrams  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

6

Wiring dimensions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

8

Terminal layout  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

9

Power ratings  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

9

Technical characteristics  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

10

INTRODUCTION

The DCTL series of thyristor modules is intended to be used in power factor correction panels where a fast compensation is required due to a very fast variation of the inductive load. They are normally controlled by a

fast power factor controller like LOVATO DCRG8-DCRG 8F series controllers, even though they are compatible with any type of fast compensation controller.

Thanks to their unique feature of having built-in current monitoring, they can detect abnormal situations occurring on the capacitor steps, signalling the problem and protecting the bank whenever possible. It

is also possible to monitor the step residual kvar power with dedicated measurement and alarms.

DCTL can operate with RS485 serial communication. In this case the connection to the DCRG 8F controller can be done through a 485 bus, and it is possible to exchange data like temperatures, step power, alarms etc

and to show them on the DCRG 8F display and/or on the remote supervision system.

The thyristor module does not require any particular programming when used with standard features. If the user wants to enable any special function like customized protections, this can be done by means of the

built-in infrared port and/or NFC communication using the same hardware and software tools used for other LOVATO devices (CX 01/CX 02 dongles, Xpress software, LOVATO SAM1 App or LOVATO NFC App).

DESCRIPTION

–    3 status LEDs (for the signalling of presence of power, operating and fault).

–    2-phase controlled switching.

–    Monitoring of the current flowing into the capacitor bank through built-in current transformers.

–    3 different mechanical sizes and 5 electrical ratings for three-phase capacitor banks from 7.5 up to 100kvar.

–    Rated line voltage:

     • 400 VAC (IEC and cULus) for DCTLA 400...

     • 400...480 VAC (IEC and cULus) for DCTLA 480...

     • 600...690 VAC (IEC), 600VAC (cULus) for DCTLA 690...

–    Thermostatically controlled cooling fan, with dedicated diagnostics (fan disconnected or jammed).

–    Can be installed both vertically and horizontally.

–    Separated switch-on command inputs for both static contact or from voltage control output.

–    Changeover relay output for global alarm or for the command of an external fan.

–    Separated auxiliary supply.

–    Double power terminals for mechanical sizes 1 and 2.

–    Integrated electronic thermal protection.

–    Internal analogue temperature sensor to protect the thyristors.

–    Optional external temperature sensor to protect the capacitor bank and/or detuning reactors.

–    Advanced self-diagnostics.

–    NFC interface for programming with smart devices (smartphone or tablet).

–    Front-mounted optical interface for programming and maintenance.

–    Isolated optional RS485 interface (mounted in a dedicated slot) with Modbus protocol for connection with DCRG 8F controller.

–    Compatible with the LOVATO SAM1 App, LOVATO NFC App, Synergy supervision software and Xpress remote control and configuration software.

–    Optional accessories for DIN rail mounting (for mechanical sizes 1 and 2).

 

                              

Infrared optical 

programming 

interface 

                            

RS485 

interface slot 

for optional 

card 

NFC 

communication 

area 

Power line 

input 

 

Auxiliary supply 

& control 

terminals 

Control 

terminals 

Capacitor bank 

connection 

 

Status LEDs 

Summary of Contents for DCTL 400 0075

Page 1: ...gigen Vorschriften installiert werden Vor jedem Eingriff am Instrument die Spannungszufuhr zu den Messeing ngen trennen und die Stromwandler kurzschlie en Bei zweckwidrigem Gebrauch der Vorrichtung be...

Page 2: ...d or NFC communication using the same hardware and software tools used for other LOVATO devices CX 01 CX 02 dongles Xpress software LOVATO SAM1 App or LOVATO NFC App DESCRIPTION 3 status LEDs for the...

Page 3: ...SAM1 App available for tablet and smartphone Android or iOS and the CX 02 Wi Fi adapter to connect to the DCTL via its front optical port The App can be used to view alarms send commands read measurem...

Page 4: ...an alarm is active Fan control relay energized when the heatsink temperature is rising Activation of the relay follows the activation of internal fan M02 PROTECTIONS Cod Description UoM Default Range...

Page 5: ...inside the panel clean filters and check cooling fan A02 External sensor overtemperature The temperature read by external NTC sensor has rised above the value set in parameter P02 04 A03 Cooling fan f...

Page 6: ...in chocked and unchoked capacitor banks It is important to keep in mind in unchoked capacitor banks that the modules can be destroyed by current transients caused by fast voltage fluctuations Also in...

Page 7: ...on is possible to monitor from the display of DCRG 8F controller the status and the measures of each DCTL thyristor module For information about the programming refer to the technical manual of DCRG 8...

Page 8: ...171 5 56 206 SIZE 2 DCTLA 400 0500 DCTLA 480 0600 DCTLA 690 0300 DCTLA 690 0500 SIZE 3 DCTLA 400 1000 DCTLA 480 1200 DCTLA 690 1000 212 195 90 25 10 60 216 97 154 275 301 DCTLA 400 1000 DCTLA 480 1200...

Page 9: ...400 400 480 480 480 480 480 690 690 690 0075 0150 0300 0500 1000 0090 0180 0360 0600 1200 0300 0500 1000 Rated operating voltage Us 400VAC 50 60Hz 400 480VAC 50 60Hz 600 690VAC 50 60Hz Rated current I...

Page 10: ...upply terminals A1 A2 Us rated voltage 100 240VAC Operating range 90 264VAC Frequency 45 66 Hz Drawn dissipated power Size 1 100 240VAC 4 6W 11 8VA Size 2 100 240VAC 5 8W 14 1VA Size 3 100 240VAC 5 8W...

Page 11: ...gigen Vorschriften installiert werden Vor jedem Eingriff am Instrument die Spannungszufuhr zu den Messeing ngen trennen und die Stromwandler kurzschlie en Bei zweckwidrigem Gebrauch der Vorrichtung be...

Page 12: ...przy u yciu tych samych urz dze sprz towych i oprogramowania kt re s stosowane w innych urz dzeniach LOVAtO electric z cza cX 01 cX 02 oprogramowanie Xpress aplikacja LOVAtO SAM1 lub aplikacja LOVAtO...

Page 13: ...OS oraz modu u Wi Fi cX 02 mo na pod czy si do DctL poprzez przedni port optyczny Aplikacja umo liwia wy wietlanie alarm w przesy anie polece odczyt pomiar w ustawianie parametr w pobieranie i wysy an...

Page 14: ...a nik wzbudzany w normalnych warunkach odzwbudzany gdy alarm jest aktywny Sterowanie wentylatorem przeka nik wzbudzany gdy temperatura radiatora wzrasta Aktywacja przeka nika nast puje po aktywacji wb...

Page 15: ...mperatura czujnika zewn trznego temperatura odczytana przez zewn trzn sond Ntc przekroczy a limit zaprogramowany w p02 04 A03 Usterka wentylatora ch odzenia Wbudowany wentylator ch odzenia dzia a niep...

Page 16: ...a ne jest aby pami ta e w przypadku kondensator w bez filtr w indukcyjnych modu y mog zosta zniszczone przez stany nieustalone pr du z powodu szybkich zmian napi cia r wnie w kondensatorach z filtrami...

Page 17: ...8F mog by monitorowane stan i pomiary ka dego modu u tyrystorowego DctL Aby uzyska szczeg owe informacje dotycz ce programowania patrz instrukcja techniczna regulatora DcrG 8F instrukcja i564 kt r mo...

Page 18: ...5 56 206 rOZMiAr 2 DctLA 400 0500 DctLA 480 0600 DctLA 690 0300 DctLA 690 0500 rOZMiAr 3 DctLA 400 1000 DctLA 480 1200 DctLA 690 1000 212 195 90 25 10 60 216 97 154 275 301 DctLA 400 1000 DctLA 480 12...

Page 19: ...Moc stopnia 400 VAc 7 5 kvar 15 kvar 30 kvar 50 kvar 100 kvar 7 5 kvar 15 kvar 30 kvar 50 kvar 100 kvar 20 kvar 33 kvar 67 kvar 440 VAc 8 kvar 16 5 kvar 33 kvar 55 kvar 110 kvar 22 kvar 37 kvar 73 kva...

Page 20: ...VAc 4 6 W 11 8 VA rozmiar 2 100 240 VAc 5 8 W 14 1 VA rozmiar 3 100 240 VAc 5 8 W 14 1 VA Napi cie zasilania baterii kondensator w zaciski L1 L2 L3 Napi cie znamionowe Us 400 VAc w przypadku DctLA 40...

Reviews: