background image

 

 

         Doc: MHIT105B1010.doc                                       11/02/2014                   

p. 3 / 5

 

 

Disposizione morsetti

  

BCG0612  -  BCG0524               

 

BCG0612  -  BCG0524   Terminal position

  

V2

LIMIT

CURRENT

20 -100%

V1

ON

CHG

ALA

REV

L

N

-

+

-

SUPPLY

BATTERY

RED

RED

YELLOW

GREE

N

STATUS LEDs

BOOST AND RELAY

SPECIAL VOLTAGE SET

CURRENT ADJUST

 

 

Disposizione morsetti

  

BCG01212  -  BCG1024               

 

BCG1212  -  BCG1024   Terminal position

  

V2

LIMIT

CURRENT

20 -100%

V1

ON

CHG

ALA

REV

L

N

-

+

-

SUPPLY

BATTERY

RED

RED

YELLOW

GREEN

STATUS LED

BOOST AND RELAY

SPECIAL VOLTAGE SET

CURRENT ADJUST

LINE FUSE

 

 

ATTENZIONE:

 

 

Riposizionare il coperchio coprimorsetti dopo il collegamento.

 

 

ATTENTION:

 

 

 Mount the terminal cover after connection.

 

 

Dimensioni meccaniche   (mm)  BCG0612  -  BCG0524                

 BCG0612  -  BCG0524 Mechanical dimensions (mm) 

    Montaggio standard (sviluppo orizzontale) 
    Standard (horizontal) mounting 

  Montaggio con accessorio BCG X00 (sviluppo verticale) 

Mounting with accessory BCG X00 (vertical mounting) 

 

 

 

 
 

 

 

 

 
 

 
 

 

 
 

 
 

 

Dimensioni meccaniche (mm)  BCG1212  -  BCG1024 

    BCG1212  -  BCG1024  Mechanical dimensions (mm) 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

145.0

150.5

63.0

198.0

206.0

212.5

129.8

Posizione etichetta dati elettrici 
Electrical data label position 

Posizione etichetta dati elettrici 
Electrical data label position 

Summary of Contents for BCG0612

Page 1: ...essorio solo versioni BCG 0612 e BCG0524 Introduction The BCG device is a battery charger working with constant voltage and constant current charge cycle suitable for lead acid batteries Different versions are available BCG 0612 12V 6A BCG0524 24V 5A BCG 01212 12V 12A and BCG1024 24V 10A The maximum current is then adjustable in a range between 20 and 100 of full scale The charging voltage is sele...

Page 2: ... to the battery poles and not to the battery charger terminals Connect the battery poles to the device battery terminals before powering on the battery charger and verify the battery connection through REV led it must be off Provide the battery charger with a fuse at the output terminals See technical characteristics Montaggio Installare il carica batterie nelle posizioni indicate nel manuale Per ...

Page 3: ... CURRENT ADJUST LINE FUSE ATTENZIONE Riposizionare il coperchio coprimorsetti dopo il collegamento ATTENTION Mount the terminal cover after connection Dimensioni meccaniche mm BCG0612 BCG0524 BCG0612 BCG0524 Mechanical dimensions mm Montaggio standard sviluppo orizzontale Standard horizontal mounting Montaggio con accessorio BCG X00 sviluppo verticale Mounting with accessory BCG X00 vertical mount...

Page 4: ... 13 5V 2 25V elemento 27 0V 2 25V elemento 13 5V 2 25V elemento 27 0V 2 25V elemento DIP 2 in V2 position 13 5V 2 25V elemento 27 0V 2 25V elemento 13 5V 2 25V elemento 27 0V 2 25V elemento Tensione di carica boost 4 4 Boost charging voltage 4 4 Corrente massima di carica Ic 6A 5A 12A 10A Max charging current 6A 5A 12A 10A Rendimento alla tensione nominale massima e alla potenza massima 86 9 89 7 ...

Page 5: ...mmq Cable cross section min max 0 2 6 mmq Dati d impiego UL Sezione conduttori min e max 30 10 AWG UL Rating Cable cross section min max 30 10 AWG Coppia di serraggio 0 5 Nm 5 LBin Tightening torque 0 5 Nm 5 LBin Connessioni alimentazione Supply connections Tipo di morsetti A vite fissi Terminal type Screw fixed Sezione conduttori min e max 0 2 2 5 mmq Cable cross section min max 0 2 2 5 mmq Dati ...