background image

©2007 LOUD Technologies Inc. All rights re served

Bass Amplifi er PCB Schematics

PAGE 2

       B-200R

12/15/05

05/30/06

C

WFB

WFB

0

1

4

CAUTION:

A

B

C

D

Tolerance:

Plot Time:

Plot Date:

E

N02128

F

4

2

NOTES:

1

Checked:

Drawn:

Released:

REV

Date

Sheet

2

of

NONE

3

Date:

5-9-05

Appvd by

3

1

A

B

C

D

E

F

2

Wed May 31, 2006

Drawing Title:

1901 Congressional, St. Louis, MO 63146

ST. LOUIS MUSIC, INC

3

Signatures:

Drawing Number:

07S673

BASS AMP

First Used On:

THE INFORMATION CONTAINED ON THIS DRAWING IS PROPRIETARY TO

Ecr(s)/Ecn(s)

Chgd By

Date

1) CAUTION: SHOCK HAZARD!!

Drawing Type:  Schematic

Drawing Size:

CONTROL  ISSUE

ADDED -02 ASSEMBLY

TOUCHING INTERNAL PARTS.

Class Code:

RLB

DESCRIPTION

3) VOLTAGES ARE MEASURED WITH 1 MEGOHM OSCILLOSCOPE

2) UNLESS NOTED, RESISTOR VALUES IN OHMS, 1/4W-5% TOL.

AND BE SURE POWER SUPPLY IS DISCHARGED BEFORE 

THAT EXPLAINED IN THE OPERATING INSTRUCTIONS.

TO AVOID RISK OF ELECTRIC SHOCK, REFER SERVICING TO QUALIFIED

CAPACITOR VALUES IN MICROFARADS, 50V-10% TOL.

AND 10 MEGOHM DIGITAL VOLTMETER.

THIS UNIT CONTAINS HAZARDOUS VOLTAGE.  DISCONNECT POWER

SERVICE PERSONNEL.  DO NOT PERFORM ANY SERVICING BEYOND 

THIS SCHEMATIC IS PROVIDED FOR USE BY QUALIFIED PERSONNEL.

12/15/05

05/30/06

C

WFB

WFB

0

1

4

CAUTION:

A

B

C

D

Tolerance:

Plot Time:

Plot Date:

E

N02128

F

4

2

NOTES:

1

Checked:

Drawn:

Released:

REV

Date

Sheet

2

of

NONE

3

Date:

5-9-05

Appvd by

3

1

A

B

C

D

E

F

2

Wed May 31, 2006

Drawing Title:

1901 Congressional, St. Louis, MO 63146

ST. LOUIS MUSIC, INC

3

Signatures:

Drawing Number:

07S673

BASS AMP

First Used On:

THE INFORMATION CONTAINED ON THIS DRAWING IS PROPRIETARY TO

Ecr(s)/Ecn(s)

Chgd By

Date

1) CAUTION: SHOCK HAZARD!!

Drawing Type:  Schematic

Drawing Size:

CONTROL  ISSUE

ADDED -02 ASSEMBLY

TOUCHING INTERNAL PARTS.

Class Code:

RLB

DESCRIPTION

3) VOLTAGES ARE MEASURED WITH 1 MEGOHM OSCILLOSCOPE

2) UNLESS NOTED, RESISTOR VALUES IN OHMS, 1/4W-5% TOL.

AND BE SURE POWER SUPPLY IS DISCHARGED BEFORE 

THAT EXPLAINED IN THE OPERATING INSTRUCTIONS.

TO AVOID RISK OF ELECTRIC SHOCK, REFER SERVICING TO QUALIFIED

CAPACITOR VALUES IN MICROFARADS, 50V-10% TOL.

AND 10 MEGOHM DIGITAL VOLTMETER.

THIS UNIT CONTAINS HAZARDOUS VOLTAGE.  DISCONNECT POWER

SERVICE PERSONNEL.  DO NOT PERFORM ANY SERVICING BEYOND 

THIS SCHEMATIC IS PROVIDED FOR USE BY QUALIFIED PERSONNEL.

-50V

+50V

2

2

PA_INPUT_A

HPGS_A

PA_INPUT_A

+16VA

J3

TO J28
SEE SHT 3
PRE AMP

2

+50V

680

R45

2

-16VA

2

R38

1K

D17

1N914

75V PIV

C34

330 pF

100V

47

R64

R51

33K

C23

33 pF

200V

-16VA

*

CW

500

AP1

BIAS

330

R63

2.0VRMS

2

2

1

C29

MPS-A06

Q3

+16VA

1K

R55

D10

10V

1N4740

D8

10V

1N4740

.33
10W

R72

R70

47

R71

47

.33
10W

R73

L1

.5 uH

.33
10W

R75

J23

1

2

3

4

5

6

7

8

J29

R48

3.3K

1/2W

R46

10K

75V PIV

1N914

D14

C35

33 pF

200V

2

3

1

U3:A

NE5532

D11

75V PIV

1N914

C44

1

2

R59

1M

4.7K

R50

D9

75V PIV

1N914

R56

47

D20

75V PIV

1N914

.33
10W

R74

R65

1

1W

FOR 07-673-01 / -02 ASSEMBLIES

-16VA

-50V

HPGS_A

R60

47K

S

D

G J112

Q10

D13

1N914

75V PIV

SEE NOTE.

BIAS AJUST

800mVRMS

220

R41

270

R67

2

D26

1N914

75V PIV

R52

680

G

D

S

IRFP-140R

Q8

G

D

S

IRFP-140R

Q5

2

.1

C26

100V

G

D

S

IRFP-9140R

Q11

26.3VRMS

G

D

S

IRFP-9140R

Q4

R57

47

VTL-5C7

OC1

S

D

G

J112

Q9

C31

10

35V

MJE-350

Q6

6

5

7

U3:B

NE5532

220

R43

270

R58

1K

R42

MJE-340

Q7

C46

10

35V

R47

1/2W

3.3K

3.3
1W

R39

* D26 ON -02 
  VERSION ONLY

TEST POINT CONDITIONS NOTE : 
    1 KHz INPUT SINEWAVE 120mV @ 0 dB 
 INPUT JACK.  120VAC LINE, VOLUME, GAIN & HP LEVEL @ "10"
TONES @ "5" , DC VOLTAGES WITH N0 SIGNAL APPLIED.

NOTE: SET BIAS VOLTAGE FROM COLD START
             ACROSS R72 - R75 ,  15 -20 mV DC
             AVERAGE , NO SIGNAL, NO LOAD.

Reviews: