background image

©2007 LOUD Technologies Inc. All rights re served

Bass Amplifi er PCB Schematics

PAGE 3

       B-200R

12/15/05

05/30/06

C

WFB

WFB

0

1

4

CAUTION:

A

B

C

D

Tolerance:

Plot Time:

Plot Date:

E

N02128

F

4

2

NOTES:

1

Checked:

Drawn:

Released:

REV

Date

Sheet

3

of

NONE

3

Date:

5-9-05

Appvd by

3

1

A

B

C

D

E

F

2

Wed May 31, 2006

Drawing Title:

1901 Congressional, St. Louis, MO 63146

ST. LOUIS MUSIC, INC

3

Signatures:

Drawing Number:

07S673

BASS AMP

First Used On:

THE INFORMATION CONTAINED ON THIS DRAWING IS PROPRIETARY TO

Ecr(s)/Ecn(s)

Chgd By

Date

1) CAUTION: SHOCK HAZARD!!

Drawing Type:  Schematic

Drawing Size:

CONTROL  ISSUE

ADDED -02 ASSEMBLY

TOUCHING INTERNAL PARTS.

Class Code:

RLB

DESCRIPTION

3) VOLTAGES ARE MEASURED WITH 1 MEGOHM OSCILLOSCOPE

2) UNLESS NOTED, RESISTOR VALUES IN OHMS, 1/4W-5% TOL.

AND BE SURE POWER SUPPLY IS DISCHARGED BEFORE 

THAT EXPLAINED IN THE OPERATING INSTRUCTIONS.

TO AVOID RISK OF ELECTRIC SHOCK, REFER SERVICING TO QUALIFIED

CAPACITOR VALUES IN MICROFARADS, 50V-10% TOL.

AND 10 MEGOHM DIGITAL VOLTMETER.

THIS UNIT CONTAINS HAZARDOUS VOLTAGE.  DISCONNECT POWER

SERVICE PERSONNEL.  DO NOT PERFORM ANY SERVICING BEYOND 

THIS SCHEMATIC IS PROVIDED FOR USE BY QUALIFIED PERSONNEL.

12/15/05

05/30/06

C

WFB

WFB

0

1

4

CAUTION:

A

B

C

D

Tolerance:

Plot Time:

Plot Date:

E

N02128

F

4

2

NOTES:

1

Checked:

Drawn:

Released:

REV

Date

Sheet

3

of

NONE

3

Date:

5-9-05

Appvd by

3

1

A

B

C

D

E

F

2

Wed May 31, 2006

Drawing Title:

1901 Congressional, St. Louis, MO 63146

ST. LOUIS MUSIC, INC

3

Signatures:

Drawing Number:

07S673

BASS AMP

First Used On:

THE INFORMATION CONTAINED ON THIS DRAWING IS PROPRIETARY TO

Ecr(s)/Ecn(s)

Chgd By

Date

1) CAUTION: SHOCK HAZARD!!

Drawing Type:  Schematic

Drawing Size:

CONTROL  ISSUE

ADDED -02 ASSEMBLY

TOUCHING INTERNAL PARTS.

Class Code:

RLB

DESCRIPTION

3) VOLTAGES ARE MEASURED WITH 1 MEGOHM OSCILLOSCOPE

2) UNLESS NOTED, RESISTOR VALUES IN OHMS, 1/4W-5% TOL.

AND BE SURE POWER SUPPLY IS DISCHARGED BEFORE 

THAT EXPLAINED IN THE OPERATING INSTRUCTIONS.

TO AVOID RISK OF ELECTRIC SHOCK, REFER SERVICING TO QUALIFIED

CAPACITOR VALUES IN MICROFARADS, 50V-10% TOL.

AND 10 MEGOHM DIGITAL VOLTMETER.

THIS UNIT CONTAINS HAZARDOUS VOLTAGE.  DISCONNECT POWER

SERVICE PERSONNEL.  DO NOT PERFORM ANY SERVICING BEYOND 

THIS SCHEMATIC IS PROVIDED FOR USE BY QUALIFIED PERSONNEL.

B+

2

B+

+180 VDC

RED

RED

2.5A

HV

+50V

+16VA

*

LINECORD

HV

FC2

2

10

C37

100V

4A

J19

J15

J12

J11

PWR SWITCH

2

D21

1N4007

1KV PIV

2

.0033

C25

250V

D23

1N4007

1KV PIV

J17

J16

2

AC
NEUTRAL

2.5A

ORG

ORG

GRN

D25

-50V

2

AC
NEUTRAL

2200
16V

C52

+12.8 VDC

2

D-GND

.1

C38

100V

.1

C32

100V

-16VA

+50V

TO
POWER
LIGHT

FC1

FUSE=
SLO BLO

J13

C28

10

450V

10
450V

C36

.0033

C50

250V

100
250V

C45

AC
LINE

D24

1KV PIV

1N4007

AC
LINE

2

D-GND

2

.047

C30

100V

2

FOR 07-673-01 / -02 ASSEMBLIES

FUSE=
SLO BLO

J11        BROWN

J7         WHT

J16        BLUE

J12        BLU/WHT

J13        BLK

CHASSIS GROUND

NET00087

NET00086

WHT

BLK

J7       VIOLET

J11       GRAY

J15        BROWN

J14        WHT

J12        BLUE

J17        BLU/WHT

J13        BLK

J20

J24

+29 VDC

1N4007

D15

1KV PIV

J9       VIOLET

J17       GRAY

100VAC
50/60HZ

230VAC
50/60HZ

AC
LINE

J9

J8

J18

J10

D16

1N4007

1KV PIV

J7       VIOLET

J11       GRAY

J15        BROWN

J14        WHT

240VAC
50/60HZ

FUSE=
SLO BLO

J12        BLUE

J13        BLU/WHT

J17        BLK

D18

2

D-GND

TO J32
SEE SHT 3
PRE AMP

R44

6.2

J21

5600
80V

C54

R66

330
10W

5600
80V

C51

BR1

KBU1004G

R68

330
10W

J22

J27

R54

2W

F1

4 A SB

R62

1

1/2W

5% FP

J6

AC
NEUTRAL

J14

1M

R61

D19

1

2

3

J33

J25

J7

EXPORT  WIRING

POWER
TRANSFORMER

100-120V  50/60Hz      4a    SB
220-240V  50/60Hz    2.5a   SB

*SEE PARTSLIST
 FOR VALUE

Reviews: