background image

Troubleshooting

Factors to check

The water does not spray

• Check if the water tank is filled.
• See if the water valve is closed.
• Check if the water filter (strainer) is clogged.

The unit is not operating

• Check if the power cord is connected.
• See if the power is turned off from the main unit. 
• See if you are correctly sitting on the seat so that 

the skin sensor switch will function properly. 

(Make sure that the Skin sensor on the seat touches your skin when you sit on the seat.)

Water is leaking

• After checking if the plumbing is correctly connected, if water is leaking

from the main unit disconnect and contact service personnel. 

Water pressure is weak

• Check if the water pressure is set at “low.” 
• Check if the water filter (strainer) is clogged.

Seat, water and 

dryer is not warm

When the nozzle doesn’t 

come out 

• See if the water temperature is set to “low.”
• Check if the dryer temperature is set to “low.” 

• See if the skin sensor on the seat is touching the skin. 

When water is cold or warm 

Body unit shakes

Dryer does not work 

• Adjust the temperature to (mid, high). 
• If someone has already used the wash function, wait about 3 minutes to use it.
• Sit on the seat for approximately 3 minutes and then use it. 

• Tighten the bolt (do not over-tighten)

• See if the skin sensor on the seat is touching the skin. 

Specification

Water

inlet type

Wash

device

Heated

seat

Warm Air

Dryer

Device

37.4°F ~ 95°F (3°C ~ 35°C)

37.4°F ~ 104°F (3°C ~ 40°C)

Elongated

Round

Dimensions

Weight (Ibs)

11.9 lbs (Packed : 16.5 lbs)11.7 lbs (Packed : 16.3 lbs)

Type

Water inlet pressure

Wash

120V / 60Hz / 660W

Direct Inlet Flow Type

0.4 ~ 7.5 kgf/cm²

Max. 700cc ±150cc / min.

Lady

Turbo

Max. 700cc ±150cc / min.

Max. 700cc ±150cc / min.

Water pressure 

adjustments

5 levels

Warm water temperature

control

Room Temp. ~ 93.2°F, 98.6 °F, 104 °F

Heater

600W

Safety device

Thermal fuse, Thermal switch, Float switch

Temperature control

Room Temp. ~ 93.2 °F, 98.6°F, 104°F 

W

5

5

Thermal fuse, Bimetal

Room temp ~ 113°F, 5 levels

250W

Thermal fuse, Bimetal

Warm air control

Safety Device

Heater

Heater

Safety device

Power rating

ATS-800

21

20

13

Inlet Water Temperature

Ambient Temperature

14

Specifications

Trouble shooting

W : 18.1inch (461mm)

: 20.6inch (525mm)

H : 7.28inch (185mm)

W : 18.1inch (461mm)

: 19.4inch (493mm)

H : 7.28inch (185mm)

Please be sure to check the following aspects before asking for help.

Summary of Contents for ATS-800

Page 1: ...improvements Importantsafeguards generalcautions are information that can protect the user from safety hazards and alsopreventlosses Pleasebesuretoreadthemanualcorrectlyforproperusage L o t u s H y g...

Page 2: ...designations Installation and cautions Initial operation Separation of the unit from toilet bowl Basic operation Detailed operation Maintenance Draining water Winter usage Trouble shooting Specificati...

Page 3: ...ending from the adapter must be connected to a permanent ground such as a properly grounded outlet box cover Whenever the adapter is used it must be held in place by the screw This appliance has to be...

Page 4: ...her when cleaning the product or detaching the unit from the toilet bowl Failure to do so can cause an electric shock Do not use a damaged power cord or a loosely fitted electric outlet This can cause...

Page 5: ...use low degree burning Special precautions should be taken for children those who cannot adjust the temperature and those who have sensitive skin For plumbing For product fixation Installation instruc...

Page 6: ...toilet mounting holes Put the bolt into the bolt case and align it with the top of the base plate Insert bolt with bolt case onto the base plate After this is done hold the bolts slide it into the bo...

Page 7: ...ectronic toilet seat and turn the water valve to the left to open it See if there is any leaking from the water hose connection Re install the toilet seat and lid that was separated when installing th...

Page 8: ...ing button the display light will change to allow the adjustment Seat temperature Low High Low High Low High Low High Low High Cautions Cautions Average maintenance time for warm water This product ca...

Page 9: ...up to 5 levels When using the wash functions use front back buttons to adjust the nozzle to fit to your body LED level Front I Back Front I Back 17 16 Nozzle position adjustment Warm air dryer adjust...

Page 10: ...rubbers on the electronic toilet seat surface which is made out of plastic material can either damage or change its color Do not spray water directly or use a shower hose on the main body unit Can cau...

Page 11: ...d high If someone has already used the wash function wait about 3 minutes to use it Sit on the seat for approximately 3 minutes and then use it Tighten the bolt do not over tighten See if the skin sen...

Page 12: ...e applicable periods specified below following the terms of this warranty Lotus Hygiene Systems Inc replacement will be warranted to the original purchaser of the products The Parts Warranty If the pa...

Reviews: