CLEANING THE STRAINER
24
MAINTENANCE
8
CLEANING THE NOZZLE
MAINTENANCE
Installation Manual and Operating Instructions
In case the nozzle is soiled and needs to be cleaned,
press “WASH”( ) button for 3 seconds without
occupying the seat, the nozzle will extend out
without spraying water.
After cleaning, Press “STOP”( ) button to
retract nozzle.
CLEANING THE BODY OF UNIT
When you clean the body, do not use “thinner”, “benzene” or “NaClO”. It causes
defects to the surface of unit.
Please use a damp cloth when you clean the unit.
Do not spray water directly on the unit.
When you clean the unit, please disconnect the power plug.
The product will not operate properly if the strainer is clogged. Please clean the
strainer regularly.
1) Close the shut off valve.
2) Flush the toilet to empty the water reservoir.
3) Unscrew the water strainer nut.
4) Clean the strainer with a small brush or water.
5) Re-screw the water strainer nut.
6) Open the shut off valve.
Existing Flexible Tube
(The water supply hose)
For ATS-1000 model use , .
*