GENERAL INFORMATION

Translation of the original instructions

13

2 GENERAL INFORMATION

2.1

Declaration of compliance

The manufacturer declares that the appliances comply with the requirements of the regulation GAR
2016/426 for the gas part and directive 2014/30/EU,2014/35/EU for the electrical part. Installation must be
performed in compliance with current regulations, especially with regard to ventilation of the premises and
the exhaust gas evacuation system.
 

·

Read the warnings in this manual carefully. They provide important information about safe installation,

use and maintenance.

·

The instruction manual must be kept for the entire duration of the equipment and made available to users

for every possible consultation. The manual should be consulted for any information concerning
installation, use and maintenance of the appliance.

·

After removing the packaging, check the integrity of the equipment.

·

All packaging materials (plastic bags, polystyrene, staples, etc.) must be disposed of in compliance with

current regulations.

·

Before connecting the appliance, make sure that the information on the data plate matches the electricity

and gas mains where the appliance is installed. The manufacturer accepts no liability if the
equipment is not connected in accordance with current regulations.

·

Always keep all parts of the equipment clean to avoid the risk of oxidation/rust and/or aggression by

chemical agents.

·

The equipment must only be used by personnel trained for the purpose.

·

The installation must be implemented by professionally qualified personnel in accordance with

the manufacturer's instructions and current reference standards.

·

The electrical safety of this equipment is only ensured when it is correctly connected to an effective

ground/earth system as required by current electrical safety standards. The manufacturer cannot be held
liable for any damage caused if the system is not connected to ground/earth.

·

Before carrying out any cleaning or maintenance tasks on the equipment, unplug it from the electricity

mains. In the event of faults or malfunctions, always deactivate the appliance.

·

Repair work of any kind must only be performed by qualified personnel.

·

This appliance must only be used for its expressly intended purpose for cooking or heating food. Any

other use is considered improper.

·

The appliance is intended for professional use and must be used by trained personnel.

·

The installation and possible transformation to another power supply voltage (if envisaged), or

transformation for operation with another type of gas, must be implemented exclusively by qualified and
authorised professional personnel.

·

Before using the appliance, carefully clean all surfaces intended to come into contact with food.

·

The manufacturer declines any and all liability for any direct or indirect damage resulting from improper

use of the equipment. The manufacturer declines any and all liability for damage caused by incorrect
installation, tampering, poor maintenance and unskilled use. Moreover, the manufacturer declines any
liability for possible inaccuracies that may be contained in this booklet attributable to errors in
transcription or printing and equally reserves the right to make any changes to the product it deems
useful and/or necessary without compromising its essential characteristics.

·

The manufacturer cannot be held liable for any damage caused by failure to comply with these

basic standards and all other use and maintenance standards contained in this booklet.

Summary of Contents for 08270450

Page 1: ...tions GAS PASTA COOKER FOR PROFESSIONAL USE CP 74G CP 76G CP 78G CPA 74G CPA 76G CPA 78G CPT 74G CPT 76G Model LIBR ISTR CP70G CON SIC Code 563006602 Review 1 Edition date 19 11 2018 Language English LOTUS S p A Via Calmaor 46 31020 San Vendemiano 39 0438 778020 39 0438 778277 ...

Page 2: ... 3 5 Water connection and drainage 19 4 BURNERS TECHNICAL DATA TABLE ITGB 20 4 1 Burners technical data table 20 5 INSTRUCTIONS FOR USE 21 5 1 General information 21 5 2 Switching the pilot burner on 21 5 3 Starting the main burner and adjusting the temperature 22 5 4 Switching the main burner off 22 5 5 Switching the appliance off 22 5 6 Emptying the tank 22 5 7 Top appliances bowl emptying 23 5 ...

Page 3: ...anslation of the original instructions 3 1 INTRODUCTION 1 1 Installation drawing FIG 1 CP 74G CP 78G CPA 74G CPA 78G A Data Plate B Electrical connection C Gas connection D Water connection R 3 4 M E Water drain R 1 M ...

Page 4: ...INTRODUCTION Translation of the original instructions 4 FIG 2 CP 76G CPA 76G A Data Plate B Electrical connection C Gas connection D Water connection R 3 4 M E Water drain R 1 M ...

Page 5: ...INTRODUCTION Translation of the original instructions 5 CPT A Data Plate C Gas connection ...

Page 6: ...INTRODUCTION Translation of the original instructions 6 1 2 Components FIG A 1 Tap knob 2 Red indicator light 3 Power button 4 On off switch 5 Hole for indicator light 6 Water discharge ...

Page 7: ...INTRODUCTION Translation of the original instructions 7 FIG C 1 By pass FIG B CP Water filling tap FIG D 1 Bracket 2 Pilot light nozzle 3 Ignition spark plug 4 Extends drainage 5 Injector ...

Page 8: ...nal instructions 8 WIRING DIAGRAM CP 74G CP 76G 1 Ignition spark plug 2 Burner ignition control unit 3 Water level control unit 4 Gas solenoid 5 Power button 6 Bipolar switch 7 Power supply terminal board 8 Level probe 9 Red warning light ...

Page 9: ...AGRAM CPA 74G CPA 76G 1 Ignition spark plug 2 Burner ignition control unit 3 Water level control unit 4 Bipolar diverter 5 Water solenoid 6 Gas solenoid 7 Bipolar switch 8 Illuminated bipolar switch 9 Power supply terminal board 10 Level probe 11 Red indicator light ...

Page 10: ...iginal instructions 10 WIRING DIAGRAM CP 78G 1 Ignition spark plug 2 Burner ignition control unit 3 Water level control unit 4 Gas solenoid 5 Power button 7 Power supply terminal board 6 Bipolar switch 8 Level probe 9 Red warning light ...

Page 11: ...NG DIAGRAM CPA 78G 1 Ignition spark plug 2 Burner ignition control unit 3 Water level control unit 4 Bipolar diverter 5 Water solenoid 6 Gas solenoid 7 Bipolar switch 8 Illuminated bipolar switch 9 Power supply terminal board 10 Level probe 11 Red indicator light ...

Page 12: ...INTRODUCTION Translation of the original instructions 12 1 3 Example installation of the appliance ...

Page 13: ...e electrical safety of this equipment is only ensured when it is correctly connected to an effective ground earth system as required by current electrical safety standards The manufacturer cannot be held liable for any damage caused if the system is not connected to ground earth Before carrying out any cleaning or maintenance tasks on the equipment unplug it from the electricity mains In the event...

Page 14: ...collection The penalties provided for in the event of improper disposal of RAEE Waste Electrical and Electronic Equipment are those provided for by the national transpositions of European Directives 2012 19 EU 2 3 Technical data table Electrical technical data table CP S70G MODEL POWER SUPPLY MAXIMUM ABSORPTION A MAXIMUM ELECTRIC POWER kW POWER SUPPLY CABLE silicon type CP 74G 230V 50 60 Hz 0 1 0 ...

Page 15: ... not install the appliance near equipment machines used in cold processes If the appliance has to be installed close to cold process equipment it is advisable to install non combustible thermal insulating material and or neutral elements between them 3 4 Electrical gas connections Before being offered for sale on the market the appliance was subjected to gas and electrical testing as required The ...

Page 16: ...t least 3 mm The connection terminal is located behind the rear wall Proceed as follows to install the power supply cable Remove the rear panel Pass the new connection cable through the cable gland connect the leads to the corresponding terminal on the terminal block and fasten them securely Lock the cable with the cable gland and refit the panel The earth ground lead must be longer than the other...

Page 17: ...eplace the screw firmly tighten and check the seal Liquid gas connection G30 G31 The liquid gas connection pressure is 30 mbar for butane and 37 mbar for propane Check the data plate measure the pressure and verify that the description of the nozzle installed matches the information provided by the manufacturer Methane gas connection H G20 The methane gas connection pressure is 20 mbar Check the d...

Page 18: ...andard Resetting the gas supply to the appliance must be possible only by hand 1 Extractor hood 2 Servo system B11 type devices See data plate Natural evacuation fig 3 Connection to an efficient natural draft fume stack by means of a windproof connection with discharge of combustion products directly to the outside Forced evacuation fig 4 The gas supply to the appliance must be directly servo cont...

Page 19: ... to a suitable drain in compliance with applicable legislation It is advisable to connect pipes without bends to avoid bottlenecks or siphon effects Water is drained by gravity Inasmuch it is essential that the drain is below the exit point of the pipe Commissioning before using the appliance clean it carefully especially the tank see the cleaning and care section Check the appliance s water conne...

Page 20: ...235 Minimum adjustment 1 100 mm 100 100 adjustable Pilot injector 25 25 41 Consumption kg h 1 498 kg h 1 476 m st h 2 010 CP 76G Burner 13 95 kW min 7 kW Burner injector 1 100 mm 2 x 130 2 x 130 2 x 205 Minimum adjustment 1 100 mm 130 130 adjustable Pilot injector 25 25 41 Consumption kg h 1 100 kg h 1 084 m st h 1 476 CPT 74G Burner 6 kW min 2 75 kW Burner injector 1 100 mm 1 x 125 1 x 125 1 x 18...

Page 21: ...re carrying out any cleaning or maintenance operation Do not operate the appliance without water in the tank 5 2 Switching the pilot burner on The corresponding burner marked on the index is indicated above each knob on the front panel When the appliance is powered up the red indicator light flashes briefly for about 1 2 second If there is no water in the tank the red indicator light continues fla...

Page 22: ...nto position The burner turns OFF and only the pilot flame remains ON 5 5 Switching the appliance off Press and turn the gas cock knob to position 0 This control blocks the gas supply to both the main burner and the pilot burner 5 6 Emptying the tank To perform this operation open the drain tap lever in vertical position which can only be reached from the door of the cabinet underneath the applian...

Page 23: ...the lever B Warning Pay close attention to the distance between the appliance and the edges of the support 5 8 Pasta cooker with automatic loading If the probe does not detect water in the tank the system resets the correct level and after 15 sec disables the heating element an alarm is signalled by the red indicator light flashing When the probe detects water again the heating element is immediat...

Page 24: ...ates an internal timer for the duration of this stage If the filling lasts continuously for more than 350 seconds the system blocks the operation of the device and an alarm is signalled by the red indicator light ON steady To reset the alarm condition first eliminate the fault that caused it to trip broken or disconnected level probes water system problems drain tap open and then switch the system...

Page 25: ...ndicated on the component itself The appliance does not require any special maintenance but during the use of the equipment it is advisable to check the following at least once a year possibly increasing the frequency depending on the degree of use The status of connections especially on the terminal board and the power supply cable as well as the status of the gas connections The operating condit...

Page 26: ...ace such parts proceed as follows GAS TAP after disassembling the front panel unscrew the gas connection screw couplings remove the coupling replace the faulty parts and install the new ones in sequence THERMOCOUPLE unscrew the pilot burner coupling unscrew the gas tap coupling in the same way and replace the element SPARK PLUG unscrew the coupling remove the damaged one and replace it SOLENDOID U...

Page 27: ...s are available commercially but a diluted solution of acetic acid can also be used To clean STAINLESS STEEL appliances it is advisable to use detergents specifically formulated for this material For minor cleaning a mild washing up liquid solution may also be used Do not wash the appliance with jets of water under pressure Avoid using detergents containing abrasive powders or bleaches of any kind...