INSTALLATION
PLEASE READ ENTIRE INSTALLATION SECTION BEFORE STARTING INSTALLATION. BE
SURE THAT ONLY QUALIFIED PERSONNEL SHOULD PERFORM THIS INSTALLATION.
MACHINE SETUP
ELECTRIC SHOCK can be fatal
Have a qualified electrician install and service this equipment.
Turn the input power OFF and unplug the machine from the
receptacle before working on this equipment.
Allow machine to sit for 5 minutes minimum to allow the power capacitors to
discharge before working inside this equipment.
Do not touch electrically hot parts.
Machine must be plugged into a receptacle that is grounded according to the National
Electrical Code and local codes.
Do not remove or defeat the purpose of the power cord ground pin.
SELECT SUITABLE LOCATION
The machine will operate in harsh environments. Even so, it is important that
standard measures are followed in order to assure the machine is long lasting and
reliable operation.
The machine must be located where there is open space such that the air
circulation in the back and out the front will not be restricted.
Avoid getting dirt and dust in the machine. Failure to observe these precautions
can result in excessive operating temperatures and the machine will shut down
by itself.
ENVIRONMENTAL AREA
Keep the machine dry. Do not place it on wet ground or in puddles. Avoid rain water.
Operating in rain is not allowed.
INPUT CABLE CONNECTION (enclose installing diagram)
Every machine has an included power cable which must be connected to
coordinated voltage class in compliance according to input voltage of cutting
machine. We recommend connecting this machine to 60A circle break under
240V and 50A circle break under 120V. If cutting machine whose power voltage
is 230V is connected wrong to AC 380V, that will cause components of inter-
machine are burned up.
Make sure power cable is connected to power switch reliably and prevent from
oxidizing.
Make sure power voltage is inside the waved range.