The LORENZ PULSE 5 metal detector is supplied with

a built-in NiMh-rechargeable battery which will power

the electronics 8-12 hours depending on the coil

connected and the environmental temperature con-

ditions. The usage time will be 10 hours under average

conditions.

A discharged battery should be recharged with the

supplied charger. Therefore the plug of the recharger

has to be connected to the charger/ext. power socket

on the rear panel of the LORENZ PULSE 5 and the

AC-plug of the charger into mains. The fast charge

electronics will automatically change to a trickel

charge mode when the battery is full. The built-in

battery is therefore protected and can't be overchar-

ged. The different charge modes are indicated via

the red light on the recharger. A permanent red light

indicates the standard state - rapid charge. A slowly

flashing red light indicates charging finished - trickel

charge. A fast flashing red light will only come on

when the temperature of the battery is out of range

or in any other fault condition.

The maximum recharge time is limited at 2,5 hours

on an empty battery. NiMh-batteries suffer from a

slow self discharge at higher temperatures. During

one month time the capacity of a battery can decrease

to 80% for example. The battery power can be simply

doubled by connecting an additional rechargeable

battery pack to the recharger/ext. power socket on

the rear panel. The usage time can be extended to

up to 24 hours. Both batteries, namely the built-in

and the external one work in parallel, therefore even

if one of the two batteries is empty it is still possible

to operate the detector.

Note:

 Never forget to turn off the detector immediately

after the red battery light on the meter comes on.

When disconnecting the recharger from the mains

it is important to disconnect the plug from the rear

panel of the LORENZ PULSE 5 (recharger/ext.

power) as well as avoiding a slow discharge of the

batteries. The supplied recharger has got a wide

range of input voltages in order to fit with any

country mains. In conjunction with the

interchangeable AC-plugs it is designed for

worldwide operation.

Four different detachable AC-plugs are available

at the manufacturer of the LORENZ PULSE 5:

USA, UK, Europe, Australia.

Note:

 Only spare parts and accessories available

from the manufacturer of the LORENZ PULSE 5

should be used.

To guarantee a long lifetime of the encased NiMh

battery pack it should never be completely

discharged, as this can result in a loss of capacity

or complete damage of the battery.

Note:

 Do never forget to turn off the LORENZ

PULSE 5 when it is not in use or when planing to

store it. Disconnect all plugs from the rear panel

when transporting it as it can’t be turned on

inadvertently when the coil connector is left open.

The LORENZ PULSE 5 has to be turned off when

the red battery light comes on!

The capacity of the built-in battery can always be

checked when turning the mode-switch to the batt

position. It will be displayed on the meter. If it is

lower than 20 the battery is nearly empty and less

than 1 hour usage time can be expected. When

disregarding the red battery light the battery can

be completely discharged. Resulting damages of

the battery can not be covered by warranty.

The battery can only be checked via the meter or

light when a coil is connected to the coil-socket of

the LORENZ PULSE 5. The encased battery pack

can be recharged at any time no matter if the

battery pack is already full or empty. It is important

to discharge the battery until the red light comes

on every fifth time the LP5 has been in use before

the detector is recharged again.

7. Battery / Recharger

The following safety information must be read

before using the rapid-charger supplied with every

LORENZ PULSE 5 detector:

l

please read the user instructions before using 

the charger

l

for indoor use only (protect against moisture)

l

never try to charge ordinary non-rechargeable 

batteries!

l

do only use to recharge 12V/3 Ah battery-packs

l

(available from manufacturer of the LP 5 only)

l

rechargeable batteries supplied with the 

LORENZ PULSE 5 contain chemical substances 

they are subject to special waste disposal.

Rapid-charger for LP5 in general

operating temperature: 

0

°

C - +40

°

C

storage temperature:  - 40

°

C - +70

°

C

input data: UE = 100-240V 

±

 10%, 50-60Hz, 700mA

Summary of Contents for PULSE 5

Page 1: ...kly affected by the size of a metal object and therefore identifies small coins as well as large pieces of metal The Detector also emits an audible sound by way of either a speaker or headphones Detection depths achieved in air tests are almost the same in the ground and therefore considerably higher than those possible with standard Pulse Induction or Sinewave VLF TR Detectors The LORENZ PULSE 4 ...

Page 2: ... small bits Large coils offer depth ranges of up to 8m 26ft Those depth capabilities for both ferrous and non ferrous metal objects can only be achieved with the Pulse Induction principle Other systems suffer from ground effects which reduce the depth range in the ground The LORENZ PULSE 5 will be able to locate objects at same depths either in the ground or in air tests The high sensitivity of th...

Page 3: ...ndition of the built in battery is displayed on the meter The meter should indicate 100 when the battery is full The LORENZ PULSE 5 can only be turned on via the mode switch when a searchcoil is connected to the coil socket on the rear panel If the LORENZ PULSE 5 is powered by external power supplies like an additional rechargeable battery con nected to the recharger ext power socket the meter wil...

Page 4: ... control also acts as a sensitivity control When it is set to the left the detector will respond up to 60 less sensitive than at the mid position The detectors sensitivity may also be increased when using a higher threshold setting than the mid position ZERO pushbutton The zero pushbutton is the most important control as the whole electronics including the discriminator and the audio will be retun...

Page 5: ...SE 5 has got a built in loudspeaker on the rear panel which gives an audible signal when the searchcoil approaches to a metal object The audio frequency will change with the distance between the searchcoil and target for better pinpointing Especially with two persons operation and large diameter coils the signal from the loudspeaker is of greater help for both persons Charger Ext power Jack To thi...

Page 6: ...or is now ready to use and will indicate a metal object immediately with an audio sound emitted by the way of loudspeaker or headphones The audio frequency will rapidly rise and attains it s highest frequency when the searchcoil is directly over the target The center of the searchcoil is the part with the highest sensitivity Even in the direct near of the target frequency changes make pinpointing ...

Page 7: ...rom the searchcoil as possible This is absolutely necessary to avoid false signals caused by metal parts of the electronics control box The searchcoil should be held at a constant height while searching In many cases it is advisible to search in a systematically manner with a certain grid which can be marked on the ground for example The small 10 inch 26 cm diameter searchcoil can be supplied with...

Page 8: ... this l Slowly move the searchcoil from the side at constant height towards the located target Try to find the center of the target with the audio As soon as a certain intensity of the audible sig nal is reached a conductivity meter reading will be performed automatically by the LORENZ PULSE 5 this will be indicated with the blue discriminator light and an indication on the meter l Compare the num...

Page 9: ...grounds electromagnetic interferences from powerlines or transmitters can course unaccurate conductivity meter readings see chapter 8 The LORENZ PULSE 5 is able to identify deeply buried big metal objects and small objects near the surface with different kinds of searchcoils Note When expecting heavily mineralized grounds it is necessary to tune the detector with the zero button to the ground Ther...

Page 10: ... can 0 33 l or up to 20 inches 50 cm on a single coin with less than 1 inch 2 5 cm diameter make this coil interesting for a lot of different search and locating purposes Those extreme depth ranges on medium sized and bigger metal objects make frame mounted searchcoils unnecessary in some cases Small items can be eliminated by increasing the distance between the coil and the ground or while select...

Page 11: ...chievable with magnetometers which are more expensive and can only detect ferrous metal objects The maximum detection depth is limited at 5 50m with this particular searchcoil Because of the size of the coil small metal fragments will be ignored Bigger nails can be identified with the target ID Most of the nails and other metal fragments can be easily eliminated by increasing the distance between ...

Page 12: ...er 11 The coil cable is protected inside the tubes and therefore can be used even under the worst environmental conditions Two adjustable carrying straps are supplied with every frame coil 1m x 2m universal cable coin compensated 2m x 2m universal cable coil 1 winding turn This is the largest frame mounted searchcoil available with the LORENZ PULSE 5 The universal cable coil has to be laid to a si...

Page 13: ... In conjunction with the interchangeable AC plugs it is designed for worldwide operation Four different detachable AC plugs are available at the manufacturer of the LORENZ PULSE 5 USA UK Europe Australia Note Only spare parts and accessories available from the manufacturer of the LORENZ PULSE 5 should be used To guarantee a long lifetime of the encased NiMh battery pack it should never be complete...

Page 14: ...se kind of interferences could also be expected In general interferences will increase with the size of the searchcoil Interferences received with large coils are often accepted in respect of the high sensitivity still offered with those particular coils In some cases interferences can be so intensive that it is simply impossible to work with the LORENZ PULSE5 Therefore it will sometimes be necess...

Page 15: ...exposed to rain or extreme temperature changes All searchcoils available for the LP 5 are waterproof When extension cables are in use please make sure that the connectors are securely fastened so that no water runs into the plugs All of the components can be cleaned from dust with a soft cloth if necessary In case of false signals or any kind of unstable operation please check the capacity of the ...

Page 16: ...s sheet 4 x 4 inches 30 in 37 in 49 in 55 in 59 in 40 in Brass sheet 8 x 8 inches 35 in 47 in 65 in 71 in 90 in 51 in Softdrink can 0 33 l 35 in 50 in 55 in 60 in 67 in 45 in Iron box 12 x7 x6 inches 51 in 71 in 87 in 102 in 122 in 70 in Fuel tank 20 l 59 in 94 in 106 in 122 in 145 in 78 in Iron plate 20 x 20 inches 63 in 86 in 98 in 114 in 142 in 79 in max range 118 in 150 in 177 in 217 in 315 in...

Page 17: ...man coin 1DM Diameter 24 mm 8 in X X X X Brass sheet 4 x 4 inches 28 in 43 in 53 in 51 in 35 in Brass sheet 8 x 8 inches 35 in 57 in 67 in 79 in 47 in Softdrink can 0 33 l 27 in 43 in 45 in 47 in 33 in Iron box 12 x7 x6 inches 50 in 86 in 102 in 106 in 63 in Fuel tank 20 l 53 in 98 in 106 in 122 in 75 in Iron plate 20 x 20 inches 57 in 94 in 114 in 118 in 75 in max range 98 in 157 in 188 in 275 in...

Page 18: ...le 380 g 1m x 1m pvc frame coil 2300 g 10 in 27 in coil 40 in coil 80 in coil 40 x80 in coil coil 3 turns 2 turns 1 turn compensated 8 Goldnugget Diameter 5mm X X X X X Goldcoin Diameter 20 mm X X X X X Silvercoin Diameter 13 mm X X X X X Silvercoin Diameter 25 mm 7 in X X X X German coin 1DM Diameter 24 mm X X X X X Brass sheet 4 x 4 inches 24 in 40 in 47 in 43 in 31 in Brass sheet 8 x 8 inches 3...

Page 19: ... searchcoil for the detection on mineralized soils l 18 inches 45 cm searchcoil with S rod shaft and armrest l 1m x 1m pvc frame searchcoil Accessory l universal coil cable 8m perimeter can be used as 0 7m x 0 7m 1m x 1m 2m x 2m compensated 1m x 2m frame mounted searchcoil controls mode switch off batt test discriminator 1 2 3 delay settings zero push button automatically retunes the electronics a...

Reviews: