7
3 4 Wiring
Figure 3: Wiring diagram
Socket
Terminal
Connection
DC input
P
connected to positive terminal of PV module
N
connected to negative terminal of PV module
AC output
M-1
connected to protective ground wire
M-2
connected to U phase of the motor
M-3
connected to V phase of the motor
M-4
connected to W phase of the motor
water level sensor input
S-1
ground
S-8
float switch 1, controlled by PR 15
S-7
float switch 2, controlled by PR 16
S-6
well probe sensor 1, controlled by PR 17
S-5
well probe sensor 2, controlled by PR 18
grounding
G
connect to proper ground
CAUTION: Ensure the exact locations of
the DC input “P” and “N” sockets
CAUTION: Ensure the wiring of AC
output is based on the marks of the
sockets
CAUTION: To ensure proper operation
of the system, select the wire size
according to the following recom-
mended principle
Prompt: Float switch 1 controlled by PR 15 and
float switch 2 controlled by PR 16 can be combined
to a dual float switch
Prompt: Well probe sensor 1 controlled by PR 17
and well probe sensor 2 controlled by PR 18 can be
combined to a dual switch well probe
Prompt: Please refer to chapter 4 3 Parameter for
further information on parameter settings
3 5 DC Disconnect switch
The pump system must be equipped with proper sized DC
disconnect switch. The switch must be installed between
solar generator and controller. It must meet the following
requirements:
minimum 800V DC
continuous current rating according to maximum cur-
rent of pump controller or higher
the switch must be rated for DC current, NOT AC
A PV disconnect switch, matching all requirements above,
can be purchased from LORENTZ.
The use of a properly sized disconnect switch is an
important safety measure and obligatory for a professional
installation of a solar pumping system.
WARNING – No disconnect switches
must be installed in power wires
between motor and pump controller
Connecting the motor wire to the
switched-on controller might
irreparably damage it Such damages