2 WARNINGS

Failure to follow
these instruc-
tions will void
the warranty.

PS150 BOOST

 IS A DC VANE TYPE PUMP. It is different

from other pumps.

This is not a submersible pump.

Before beginning installation procedures, these
installation and operating instructions should be
studied carefully.

The installation and operation should also be in
accordance with local regulations and accepted
codes of good practice.

This INSTRUCTION MANUAL contains maintenance
information, and is the property of the pump owner

Please give this manual to the pump owner or mainte-
nance personnel when you are finished!

Please note: The
pump must only
be used in clean
fresh water.

3 DIMENSIONS

315/327

210

100

38/48

65/86

M

2

9

x

1

.5

3/8” - 18 NPT
1/2” - 14 NPT

3/8” - 18 NPT
1/2” - 14 NPT

INLET

OUTLET

130

120

80

38

1

1

2

/1

2

6

26/32

6

3

4-O8.5

Summary of Contents for PS150 Boost

Page 1: ...PS150 BOOST INSTRUCTIONS FOR INSTALLATION OPERATION SERVICE Copyright 2004 2005 2006 2007 by BERNT LORENTZ GmbH CoKG all rights reserved...

Page 2: ...urface pump which cannot be submersed The pump of PS150 BOOST is a positive displace ment vane type pump The PS150 BOOST brushless DC motors are specially made for this system The motor is using very...

Page 3: ...lation and operation should also be in accordance with local regulations and accepted codes of good practice This INSTRUCTION MANUAL contains maintenance information and is the property of the pump ow...

Page 4: ...ry Type Quantity of Solar Modules panels Solar Module Type Pump Model Pump Serial Controller Model Controller Serial Installer Record the following Installation Date Installed by Cut in Pressure bar P...

Page 5: ...ler close to the solar array not the pump This will reduce the risk of lightning damage Protection from heat Electronic devices are most reliable when they are protected from heat Mount the controller...

Page 6: ...itoring SOURCE LOW Red light Water level is low After recovering the motor will start within 20 minutes Red light will remain ON to indicate low water level has occurred For Reset press the ON OFF swi...

Page 7: ...y in a trench Therefore make sure inlet lines and fittings are FLUSHED CLEAN before hooking up to pump The INLINE FILTER may have a red push button valve to release pressure for maintenance If filter...

Page 8: ...secure the pump to the motor BEFORE installing the pump drop a teaspoon of water into the inlet and run the pump HANDLE YOUR PUMP CAREFULLY Never hammer on it clamp it in a vice or drop it To PREVENT...

Page 9: ...e Reverse the wires if necessary so that pump turns CLOCKWISE looking from purtip end If water flow becomes blocked or if the pump jams or freezes and cannot turn freely the motor will draw excessive...

Page 10: ...y to battery bank Remote Tank Float Switch Con nect float switch to terminals 4 5 of the pump controller when it breaks contact on rise to turn the pump OFF Otherwise use terminals 3 4 for opposite fu...

Page 11: ...e Pump ON Pump Speed Well dry Tank full Battery status 9 5 System Wiring for 12 24 V Solar Direct Operation L 1 L 2 L 3 low water sensor probes connect for battery mode remote float switch Battery or...

Page 12: ...o measure the current used by your pump with an amp meter in series with the line your system metering Current draw will rise in direct proportion to outlet pressure Pressure should NOT be set beyond...

Page 13: ...oo large to fit peel away some fibers using a knife End caps MUST fit snugly or dirt will enter 1 Connect to Float switch terminal 4 of PS Controller 2 Connect to float switch terminal 5 or 3 dependin...

Page 14: ...Rebuild Exchange Service There should be almost no vibra tion of pressure gauge needle FILTERCLOGSFREQUENTLY 1 INTAKETOOCLOSEto bottom of well stream tank etc Raise it as high as feasible to reduce in...

Page 15: ...ut in pressure Turn power off and release water pressure before setting pre charge Modern captive air tank will not need pre charging again GALVANIZED TANK without air bladder MUST BE RECHARGED with a...

Page 16: ...Copyright 2004 2005 by BERNT LORENTZ KG all rights reserved Bernt Lorentz GmbH Co KG Heidekoppel 16 D 24558 Henstedt Ulzburg Germany Tel 49 4193 7548 0 Fax 49 4193 7548 29 www lorentz de info lorentz...

Reviews: