![LORD 3DM-GX5-35 Manual Download Page 41](http://html1.mh-extra.com/html/lord/3dm-gx5-35/3dm-gx5-35_manual_1939347041.webp)
3DM
®
-GX5-35
DCP Manual
GNSS Message
Format (use new
settings)
Desc count: 0x02
1st Descriptor: 0x03
Data Rate: 0x0004
2nd Descriptor: 0x05
Data Rate: 0x0004
Reply Field :
ACK/NACK
0x75
0x65
0x0C
0x04
0x04
0xF1
Echo cmd: 0x09
Error code: 0x00
0xE8
0xBC
Command:
GNSS Message
Format (read
back current set-
tings)
0x75
0x65
0x0C
0x04
0x04
0x09
Function: 0x02
Desc count: 0x00
0xF9
0xF3
Reply Field 1:
ACK/NACK
0x75
0x65
0x0C
0x0D
0x04
0xF1
Echo cmd: 0x09
Error code: 0x00
Reply Field 2 :
Current GNSS
Message Format
0x09
0x81
Desc count: 0x02
1st Descriptor: 0x03
Data Rate: 0x0004
2nd Descriptor: 0x05
Data Rate: 0x0004
0x8D
0xFE
Copy-Paste version of the commands:
Use New Settings: ”7565 0C0A 0A09 0102 0300 0405 0004 1685”
Read Current Settings: “7565 0C04 0409 0200 F9F6“
41