![LORD 3DM-GX5-35 Manual Download Page 39](http://html1.mh-extra.com/html/lord/3dm-gx5-35/3dm-gx5-35_manual_1939347039.webp)
3DM
®
-GX5-35
DCP Manual
Format (use new
settings)
1st Descriptor: 0x04
Rate Dec: 0x000A
2nd Descriptor: 0x05
Rate Dec: 0x000A
Reply Field :
ACK/NACK
0x75
0x65
0x0C
0x04
0x04
0xF1
Echo cmd: 0x01
Error code: 0x00
0xE7
0xBA
Command: IMU
Message Format
(read back cur-
rent settings)
0x75
0x65
0x0C
0x04
0x04
0x08
Function: 0x02
Desc count: 0x00
0xF8
0xF3
Reply Field 1:
ACK/NACK
0x75
0x65
0x0C
0x0D
0x04
0xF1
Echo cmd: 0x08
Error code: 0x00
Reply Field 2 :
Current IMU
Message Format
0x09
0x80
Desc count: 0x02
1st Descriptor: 0x03
Rate Dec: 0x000A
2nd Descriptor: 0x04
Rate Dec: 0x000A
0x98
0x0F
Copy-Paste version of the commands:
Use New Settings:”7565 0C0A 0A08 0102 0400 0A05 000A 22A0”
Read Current Settings: “7565 0C04 0408 0200 F8F3“
39