node will resume the state it was in when the "Idle" command was sent. If the "Resume" command
is sent
after enabling the IMU Data Stream, the node will continue streaming. (reply is ACK/NACK).
MIP Packet Header
Command/Reply Fields
Checksum
SYNC1
“u
SYNC2
“e”
Descriptor
Set byte
Payload
Length
Field
Length
Cmd.
Desc.
Field Data
MSB
LSB
Command:
Resume
0x75
0x65
0x01
0x02
0x02
0x06
N/A
0xE5
0xCB
Reply:
ACK/NACK
0x75
0x65
0x01
0x04
0x04
0xF1
Cmd echo: 0x06
Error code: 0x00
0xDA
0x74
Copy-Paste version of the command: “7565 0102 0206 E5CB”