page 46
List of error codes
Code designation
cause
remedy
E 00
no program
operating system and welding program doesn’t
match to each other
store welding programs matching to the operating
system version, into the machine
E 01
thermal overload
temperature of power units are too high
let machine cool down in standby (*1)
E 02
mains overvoltage
mains voltage too high (24V supply > 36V)
check mains voltage and control transformer (*2)
E 03
secondary overcurrent
welding current is too high
check current sensor and its wiring
E 05
cooling system error
flowrate of the cooling liquid is too low
(< 0.3 l/min)"
check connectors of flow-meter, level of cooling
liquid and flowrate (*3). See page 36
E 06
secondary overvoltage
Master detects output voltage is too high
-check power unit
-check ground connection
E 07
EEProm checksum error
no welding program stored or error during rea-
ding from memory
transfer welding programs to machine again
E 09
V/A measuring error
external current/voltage or measure-difference
between Master and Process
check wiring of current sensor and pc-board DK-
UFI
DC machines: check DK-KSDCN
AC machines: check IGBTs
E 10
torch connection
short circuit of torch control cables or between
torch switch wires and welding potential
check torch control cables and torch interface
E 11
remote-control conn.
short circuit between remote control cables
check remote control and wiring of remote control
E 12
Communication Process
Process is not responding to Master
switch the machine off and on again
optionally exchange pc-board DK-MAPRO
E 13
Temp. sensor error
Temp. sensor is defective
check resistor value and wiring of the sensor
E 14
Op. voltages error
supply voltage is too low (24V < 17V)
check mains voltage and control transformer (*2)
E 16
primary overcurrent
protection1
-power consumption of power unti 1 is too high
-PE protection became active
-check DK-DCDRV and MOSFETs of power unit1
-check ground cable and wiring of power unit
E 17
Error current symmetry
output difference between power units
check power units (*4), see page 34
E 19
Ignition unit error
no response of ignition unit to pc-board DK-
MAPRO
check/exchange pc-board DK-HFDC
E 20
Overvoltage sec.
Process is measuring a too high output voltage or
no voltage at all
check wiring of the output sockets to DK-MAPRO
check power unit
E 21
Output voltage/current
external current/voltage or measure-difference
between Master and Process
check wiring of current sensor and pc-board DK-
E 22
Mains undervoltage 1
power unit 1 reports mains voltage too low
check mains voltage and mains rectifier
E 23
Mains overvoltage
power unit reports mains voltage too high
check mains voltage, see page 42
E 24
Overcurrent protection2
power consumption of power unti 2 is too high
check DK-DCDRV and MOSFETs of power unit 2
E 25
Power module detection
Jumper on pc-board DK-DCDRV or pc-board DK-
ACDRV have been set wrong
check Jumper J1, J2 on pc-board DK-DCDRV (by
AC machines check also Jumper 1 on pc-board
DK-ACDRV), see page 43
E26
Synchronisation error
communication between the machines is not
working properly
check optical cable between both machines and
settings of each machine (Synchro Master-Slave
setting)
E 29
AC Overvoltage
ignition voltage in zero-crossing is too high
check IGBTs
E 30
Mains undervoltage 2
power unit 2 reports mains voltage too low
check mains voltage and mains rectifier
E 31
Communication error
Master is not responding to Process
switch the machine off and on again
optionally exchange pc-board DK-MAPRO
(*1) display the module temperatures in menu Extras > Diagnosis > Module temperatures
(*2) display the supply voltages in menu Extras > Diagnosis > Op. voltages 15V / 24V
(*3) display the flow rate in menu Extras > Diagnosis > Flow rate cooling system
(*4) display the welding current of the mudules in menu Extras > Diagnosis > Current module 1 / 2