page 42
Monitoring bus voltage
The bus voltage is monitored by the DSP (Process) directly. As soon as the bus voltage is too low or too high, the
machine will stop and displays the corresponding error message:
E22
: Mains undervoltage 1
E23
: Mains overvoltage
E30
: Mains undervoltage 2
Should the mains voltage be too low at both power units (only at V40 or V50), only the error message with the
highest number is displayed (
E30
).
Schematic
LED6
DCDRV1
X1 / 10
X1 / 4
X2 / 10
X2 / 4
CPLD
DSP
+15V
DCDRV2
DK-MAPRO
LED4
X1 / 9
X2 / 9
+15V
LED6
X1 / 10
X1 / 4
X3 / 10
X3 / 4
+15V
LED4
X1 / 9
X3 / 9
+15V
+U bus1
-U bus1
+U bus2
-U bus2
max. bus volt ok
min. bus volt ok
max. bus volt ok
min. bus volt ok
Voltage limits
bus voltage
LED4 LED6
optocoupler output
min. bus volt. ok (pin 10)
optocoupler output
max. bus volt. ok (pin 9)
error message
0 - 250V
on
off
high
low
E22, E30
255V - 700V
on
on
low
low
-
705V -
∞
off
on
low
high
E23