Pc-board DK-DCDRV
The pc-board DK-DCDRV is managing the primary drive level of the power unit.
Functions
- encoding power unit
- connection of the thermal sensor (at heat sink)
- supply current sensor
- monitoring bus voltage and supply voltage
- safety shut-down of power unit
- passthrough signal power-up relay
- passthrough output of current sensor
Encoding power unit
The type of the power unit is set via the DIP switch.
DIP 1 DIP 2
setting
type
OFF
OFF
240 A
V24, V40
OFF
ON
270 A
V27
ON
OFF
300 A
V30, V50
ON
ON
reserviert
LED displays
normal
LED
state designation
1 (red)
off
primary overcurrent shut down
2 (green)
on
drive level of low-side is ok
4 (green)
on
bus voltage max is ok
5 (green)
on
drive level of high-side is ok
6 (green)
on
bus voltage min is ok
malfunction
LED
state reason
1 (red)
on
primary current is too high, power unit has been switched off
2 (green)
never on no drive level low-side
4 (green)
off
bus voltage is too high (e.g. mains overvoltage)
5 (green)
never on no drive level high-side
6 (green)
off
bus voltage is too low (e.g. mains voltage too low)
Measuring Points
designation
measure point
result
supply voltage current sensor
X2/1
X2/6
+
gnd
+15V DC
supply voltage current sensor
X2/3
X2/6
-
gnd
-15V DC
temperature sensor
X3/1
X3/2
gnd
+
10k
W
at 25°C
(about +2V DC)