Messages, fault rectification
909.2099.9-02
- 15 -
06.15
8
Messages, fault rectification
8.1 Welding operation
Flash code
Error
Rectification
Charge condition indica-
tor (3)
The first LED
flashes green/
yellow alter-
nately
Welder not connected to the
battery
Connect battery to welder at the lat-
est within 15 seconds of button on
The first LED
flashes yellow
The battery is flat, further work
-
ing is not possible
The battery needs charging
The first LED
shows constant
yellow
Reserve operation: Continued
working is possible
Charge the battery after 1-2 elec-
trodes
Fault indicator (8)
Continuous light Cell temperature too high
Allow the battery to cool down and
then operate at the correct operating
temperature
1x flash
Over-current error on welder
Replace the welder or consult the
service department
2x flashes
Cell temperature too low
Operate in the correct range of
operating temperatures
3x flashes
Cell over-voltage
Consult service department
4x flashes
Cell under-voltage
Connect the battery to the charger or
consult service department
5x flashes
Error voltage at the casing
Consult service department
6x flashes
Cell voltage differences
Consult service department
7x flashes
8x flashes
Electronic fault
Consult service department
8.2 Charging the battery
Flash code
Error
Rectification
Charge condition indica-
tor (3)
The first LED
flashes green/
yellow alter-
nately
No charging current
Check the charger or consult the
service department
Fault indicator (8)
Continuous light Cell temperature too high:
Allow the battery to cool down and
then operate at the correct operating
temperature
2x flashes
Cell temperature too low
Operate in the correct range of
operating temperatures
3x flashes
Cell over-voltage
Consult service department
4x flashes
Cell under-voltage
Consult service department
6x flashes
Cell voltage differences
Consult service department
Summary of Contents for MobilePower 1
Page 3: ... 909 2099 9 02 3 06 15 II III ...
Page 82: ... 82 06 15 909 2099 9 02 ...
Page 83: ...909 2099 9 02 83 06 15 ...