5
Operation Instructions
1.Connecting the System
2.Turn On the System
1.1
Connect the power cord into a
properly grounded electrical outlet
with a sufficient amperage rating.
1.2 VOLTAGE
120 Volt
– The GS-205B requires a full 10
amp grounded circuit for 120 volt
operation.
240 Volt
–The GS-205B requires a full 7
amp grounded circuit for 240 volt
operation.
1.3 EXTENSION CORDS
If used, should
be as short as possible and not less
than 12 gauge.Heavy duty cords are
recommended.
1.4 CIRCUITS
that have less than 10 amps or
that have other high demand equipment
or appliances(especially more than one
heat seal machine) plugged in, should not
be used.
NOTE:
If the supply cord is damaged, it
must be replaced by the
manufacturer, its service agent or
a similarly qualified person in
order to avoid hazard.
CAUTION :
Failure to follow these instructions will cause:
1) Erratic controller functions.
2) Inaccurate displays and slow heat-up.
3) The circuit breaker to disengage.
2.1 Switch The System On(figure2.1)