56 Installation
(for qualified installers only)
© Travis Industries
11/9/20 - 1503
PB36 CF Install (Aust)
CoolSmart TV - Installation Overview (Optional)
The CoolSmart system is designed to redirect the convective heat of the fireplaces from the front of the unit, just
above the glass, to a location higher on the wall. The use of this kit allows for reduced clearances to televisions
and a recessed cavity above the fireplace. When using this kit, disregard the framing dimensions in the manual
and follow the framing instructions included in this instruction sheet. See the installation manual for further
requirements.
When used on the PB 36 CF, this kit allows for the
non-combustible facing height to be reduced
. See
illustration below for details.
Min. 1-1/2" (39mm)
Max. 120"
(3048mm)
Min. 73-3/4"
(1690mm)
Non-Combustible
Facing Only
Ceiling
ProBuilder
36 CF
Fireplace
Optional Recessed Pocket
Min. 35"
(889mm)
Combustible Facing
Allowed
Min. 45-1/2"
(1156mm)
Max. 3-1/2"
(89mm)
Television
Min. 1/4"
(7mm)
to the top of
the zero-clearance box