Installation
(for qualified installers only)
25
© Travis Industries
11/9/20 - 1503
PB36 CF Install (Aust)
Vent Configurations
Minimum Vent Configuration
Use 5x8” Diameter Coaxial Vent
NOTE
: Use the included thimble assembly whenever passing through a wall. (use on front
and back of wall penetration). See picture below.
The termination must fall within the shaded area shown in the chart. Use the indicated
restrictor positions.
One 45° elbow may be used on the horizontal run.
HINT
: Use minimum vent kit “H” (96200332) from Travis Industries (additional vent may be
required).
Use the included wall thimble when
penetrating a wall. Part #96200101
3 feet (0.915m)
0 feet
0 feet
Max. 15' (4.5M) Horizontal Section(s)
Exhaust Restrictor # 1 (stock)
Diffuser Closed (stock)
5 feet (1.5 m)
10 feet (3 m)
15 feet (4.5 m)
1' Section Place Directly
on Fireplace (required)
Approx.
53-1/2"
1359mm