Installation
(for qualified installers only)
9
Travis Industries
4041220
9 3 5 0 8 1 2 3
Approved Vent Configurations
Restrictor Position
•
A vent restrictor is built
into the appliance to
control the flow rate of
exhaust gases. This
ensures proper flames
for the wide variety of
vent configurations. The
restrictor consists of a
butterfly valve in the air
inlet and an adjustment
plate with index holes
used to hold the valve in
a fixed position.
Depending upon the
vent configuration, you
may be required to adjust
the restrictor position.
The charts for approved
vent configurations
describe which position
the vent restrictor must
be in.
Loosen the four screws
holding the stove top in
place.
a
b
Lift the stove top off the top. If
the vent is attached, you may
prop the stove top with wood
to allow access to the
restrictor.
To Adjust the Restrictor
To Access the Restrictor
Slide the restrictor
adjustment rod in.
b
Replace the cotter pin through
the correct hole on the restrictor
adjustment rod.
c
This restrictor is
in position # 6
NOTE:
The restrictor is
shipped in
position #1.
Lift the cotter pin out.
a
Restrictor
Positions
# 2
# 4
# 6
# 3
# 5
# 1
AAAA
AAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAA
AAAAAAA
AAAAAAA
AAAAAAA
AAAAAAA
1/4" Nutdriver
Elbows
•
3 Elbow
maximum
(or four 45°
elbows)
Measuring
Vent Lengths
Vent Horizontal Run
(measure from the closest
edge of the starter section to
the end of the termination)
Vent Height is
calculated to the top of
the vent on horizontal
terminations and to the
top of the termination on
vertical terminations.
Vent
Height
The starter
section is 1/2"
above the top