Loop Telecom Loop-O9500 Manual Download Page 6

 

Loop-O9500-R-12FXS-

 

sn-

pt

-

G

 

12-channel FXS plug-in card with 600/ 900 
Impedance, Battery Reverse, PLAR, without 
Ground Start and Metering Pulse. Used with 12 
RJ11. 

Loop-O9500-R-12FXS-P-sn-

pt

-

G

 

12-channel FXS plug-in card with 600/ 900 
Impedance, Battery Reverse, PLAR, without 
Ground Start and Metering Pulse PLAR bit 
programmable function. Used with 12 RJ11. 

Loop-O9500-R-12FXS-M-

pt

-

G

 

12-channel FXS plug-in card with 600/ 900 
Impedance, Battery Reverse, PLAR, [Metering 
Pulse]. Used with 12 RJ11. 

Loop-O9500-R-12FXS-MPP-

pt

-

G

 

12-channel FXS plug-in card with 600/ 900 
Impedance, Battery Reverse, PLAR and PLAR 
bit programmable function, [Metering Pulse]. 
Used with 12 RJ11. 

Loop-O9500-R-12FXS-GS-

pt

-

G

 

12-channel FXS plug-in card with 600/ 900 
Impedance, Battery Reverse, PLAR, [Ground 
Start] . Used with 12 RJ11. 

Loop-O9500-R-12FXS-GM-

pt

-

G

 

12-channel FXS plug-in card with 600/ 900 
Impedance, Battery Reverse, PLAR, [Ground 
Start, and Metering Pulse]. Used with 12 RJ11. 

Loop-O9500-R-12FXS-GMP-

pt

-

G

 

12-channel FXS plug-in card with 600/ 900 
Impedance, Battery Reverse, PLAR and PLAR 
bit programmable function, [Ground Start, and 
Metering Pulse]. Used with 12 RJ11. 

12FXS-GMP includes all FXS Card 
functions. 

 

“12FXS-x” cards with H/W ver.

 L 

and 

F/W V.3.01.01 or newer versions.  
It  can also be used in the 
Loop-AM3440-A /B/C 

 

For 

sn

 option, please refer to the 

table below for detail information.

 

   

pt

= power type 

   
   

For 

pt

 option, please refer to the table 

below for detail information

 

Loop-O9500-R-12FXO-

G

 

12-channel FXO plug-in card with 600/ 900 
Impedance, Battery Reverse, without Ground 
Start and Metering Pulse. Used with 12 RJ11. 

Loop-O9500-R-12FXO-M-

G

 

12-channel FXO plug-in card with 600/ 900 
Impedance, Battery Reverse, [ Metering Pulse ] 
Used with 12 RJ11. 

Loop-O9500-R-12FXO-GS-

G

 

12-channel FXO plug-in card with 600/ 900 
Impedance, Battery Reverse, [ Ground Start ] 
Used with 12 RJ11. 

Loop-O9500-R-12FXO-GM-

G

 

12-channel FXO plug-in card with 600/ 900 
Impedance, Battery Reverse, [ Ground Start, 
and Metering Pulse ] Used with 12 RJ11. 

12FXO-GM includes all FXO Card 
functions. 
 

“12FXO-x” cards with 

H/W ver. G 

and 

F/W V2.01.01

 or newer versions.  It  

can also be used in the AM3440-A /B/C

 

Loop-O9500-R-TDMoE-PPM-

G

 

TDMoE card with 2 GbE combo interfaces and 2 

Ethernet interfaces (10/100/1000BaseT) plug-in 
module 
Support G.823 Traffic  

The SFP module is not included in the 
TDMoE card.  
Please order seperately for SFP optical 
modules listed in the table below. 

Low Speed Tributary Modules (Dual Slots) 

Loop-O9500-R-6X21A-

G

 

6-channel X.21/V.11 card with DB15 connector 

Loop-O9500-R -6V35A-

G

 

6-channel V.35 plug-in card with DB25S 
connector, for M34.  (2Mbits per channel) 
Please order conversion cable connector below.

Loop-O9500-R -6V36A-

G

 

6-channel V.36 card with DB25 connector via 
conversion cable to DB37 

Loop-O9500-R-6E530A-

G

 

6-channel EIA530 plug-in card with DB25 
connector 

Loop-O9500-R-6RS449A-

G

 

6-channel EIA530/RS449 plug-in card with DB25 
connector via conversion cable to DB37  

These cards will occupy two slots. 
These cards can also be used in the 
Loop-AM3440-A /B/C.  

 

Loop-O9500-R-24FXS-sn-

pt

-

G

 

24-channel FXS plug-in card with 600/900 
Impedance, Battery Reverse, Loop Start and 
PLAR Without Ground Start and Metering Pulse

Loop-O9500-R-24FXS-P-sn-

pt

-

G

 

24-channel FXS plug-in card with 600/900 
Impedance, Battery Reverse, Loop Start, PLAR 
and [PLAR bit programmable]. 
Without Ground Start and Metering Pulse 

24FXS-GMP includes all FXS card 
functions. 

 

These cards will occupy two slots. 
These cards can also be used in  the 
Loop-AM3440-A /B/C 
 

Summary of Contents for Loop-O9500

Page 1: ...on blocking DS0 cross connect fabric with LS modules The 6U shelf supports 4 HS tributary module slots 6 LS tributary module slots With up to 10 optical STM 1 OC 3 or 5 optical STM 4 OC 12 or 10 elect...

Page 2: ...rs without line power 12 channel G SHDSL 2 pairs without line power 4 channel G SHDSL 1 pairs without line power 24 channel G SHDSL 1 pairs without line power 8 channel G 703 card at 64 Kbps data rate...

Page 3: ...Bridge Router x x x x x x 8 48 G SHDSL x x x x x x 2 4 12 24 3 E1 x x x x x x 3 18 G 703 x x x x x x 8 48 C37 94 x x x x x x 1 4 4 24 Dry Contact x x x x x x 8 48 Dry Contact type B x x x x x x 8 48...

Page 4: ...E1 120 ohm or 63 T1 software programmable plug in card This card can also be used in the Loop O9400R Loop O9500 R 16E75 G 16 E1 75 ohm plug in card Order two for redundancy This card can also be used...

Page 5: ...54 encoding with 8 RJ48 connectors for 8 RS232 Async ports This card can also be used in the Loop AM3440 A B C Loop O9500 R 8RS232 DB G 8 port RS232 plug in card with X 50 subrate multiplexing scheme...

Page 6: ...ith 600 900 Impedance Battery Reverse Metering Pulse Used with 12 RJ11 Loop O9500 R 12FXO GS G 12 channel FXO plug in card with 600 900 Impedance Battery Reverse Ground Start Used with 12 RJ11 Loop O9...

Page 7: ...will occupy two slots These cards can also be used in the Loop AM3440 A B C Accessories SFP Optical Modules Please place your order using the 5 digit alphanumeric codes listed in the separate SFP Opti...

Page 8: ...6TE G 1u 16 port Y box panel in E1 120 ohm or T1 for two SCSI to two TELCO 50 E1 120 ohm or T1 connectors 12 ports to the first TELCO connector 4 ports to the second TELCO connector without cable Usin...

Page 9: ...VV B G 1 for 1 protection Y Box with BNC connectors 4 E1 Used with 4E1 Loop VV R G 1 for 1 protection Y Box with RJ48C connectors 16 E1 Used with 4E1 Loop VV T G 1 for 1 protection Y Box with RJ48C co...

Page 10: ...to be ON HOOK when an alarm occurs Jumper selectable for all channels Note For S customer s special bit please refer to SFP brochure or contact your nearest Loop sales representative For Magneto Card...

Page 11: ...ppm Jitter ITU G 823 Line Code AMI HDB3 Framing Unframed with a framing monitor on receiving side Input Signal ITU G 703 Impedance 75 ohm coax 120 twisted pair Output Signal ITU G 703 Connector SCSI I...

Page 12: ...ITU G 703 Electrical 75 ohm Coax 120 ohm twisted pair Output Signal ITU G 703 Jitter ITU G 823 Function Support DS0 SNCP G shdsl Line Interface 2GH 4GH Number of ports 2 or 4 Line Rate for 4 channel...

Page 13: ...port Interface RS232 V 24 Data Port Up to twelve 8 port RS232 cards MUX Maximum 5 subrate port per 64K bps Mux mode 0 6K 1 2K 2 4K 4 8K 9 6K Asynchronous Independent mode 0 6K 1 2K 2 4K 4 8K 9 6K 19...

Page 14: ...g for communications between magneto telephones Use Magneto card PLAR mode setting for communications between a magneto telephone and a regular telephone Voice Card 12FXS 12FXO 24FXS 24FXO Connector 1...

Page 15: ...ng 2 sec on 4 sec off for 1 min or 1 sec on 2 sec off for 30 sec programmable Signaling Loop Start DTMF E M Voice Interface Connector Two RJ45 Encoding G 723 Impedance Balanced 600 ohms Longitudinal C...

Page 16: ...cy support for all types of packet types including IEEE 802 1q VLAN and 802 1ad Q in Q QoS User configurable 802 1p CoS ToS in out going IP frame Ingress packet Rate limiting buckets per port for ethe...

Page 17: ...m x 92 8mm Ring Voltage 40 55 VRMS Configurable Ring Frequency 10Hz 40Hz Ring Waveform Trapezoidal and Sinusoidal Max Ringer Load 3 REN On hook off hook Characteristics On hook voltage tip ring 50 V N...

Page 18: ...I SDH Lo Path TU LOP TU AIS LP SD LP SF LP UNEQ LP PLM LP TIM LP RDI P LP RDI S LP RDI C LP REI LP BIP Line LOS PI LOF S TIM S SD L SF L AIS L RDI L REI L UAS B1 BIP B2 BIP STS Path LOP P AIS P SD P S...

Page 19: ...32 16 3 7 8 1 2 1 Note 2 TRIB 3 63 32 16 3 7 8 1 1 X HS TRIB 4 63 32 16 3 7 8 1 1 X XCU 1 X X X X X 2 2 XCU 2 X X X X X 2 2 Maximum Port of Each Interface 252 12 28 32 4 10 5 Figure 2 High speed trib...

Page 20: ...rth America Tianjin China 8F No 8 Hsin Ann Road 6F No 36 Alley 38 Lane 358 8 Carrick Road No 240 Baidi Road Science Based Industrial Park Rueiguang Road Palm Beach Gardens Nankai District Hsinchu Taiw...