18
Diagnostics
XCU card
Loopback Test
Local loopback, payload loopback, line loopback
BERT Test
Optical interface
Direction: to optical lines
B155/622 card
Loopback Test
Local loopback, payload loopback, line loopback:
BERT Test
Optical interface
Direction: to optical lines
E1/T1 card
Loopback Test
Local loopback, line loopback:
BERT Test
E1/T1 interface
Direction: to optical lines, to tributary lines
Performance Monitor
Performance Reports
Performance Parameters: Error Block (EB), Background Block Error (BBE), Error Second(ES), Burst
Error Second (BES), Severe Error Second (SES), Unavailable Second(UAS)
System Alarm
Alarm Cut Off, Power Loss/Uneqp, Fan Fail, Fan Module Uneqp,
Overheat, TS Sync Loss, Logon and Logout, Optical Port Uneqp, Card In,
Card Out, Card Type Mismatch, Card Port Number Mismatch, Card Fail,
Card Registration, SNCP Switch, MSP Switch, Trib Protection Sync, Standby
XCU Takeover, Standby Trib Takeover, XCU Sync, SFP Tx Fail, SFP Rx Fail,
SFP Temperature, LS Protection, LS ID Mismatch
Line
PI-LOS RS-LOF RS-TIM MS-SD MS-SF MS-AIS
MS-RDI MS-REI B1-BIP B2-BIP
Ho-Path AU-LOP AU-AIS HP-SD HP-SF HP-UNEQ HP-PLM
HP-TIM HP-RED-P HP-RDI-S HP-RDI-C HP-LOM
HP-REI
SDH
Lo-Path
TU-LOP TU-AIS LP-SD LP-SF LP-UNEQ LP-PLM
LP-TIM LP-RDI-P LP-RDI-S LP-RDI-C LP-REI LP-BIP
Line
LOS-PI, LOF-S, TIM-S, SD-L , SF-L ,
AIS-L , RDI-L , REI-L UAS, B1-BIP, B2-BIP
STS-Path LOP-P, AIS-P, SD-P, SF-P, UNEQ-P, PLM-P, TIM-P,
RDI-P-P, RDI-S-P, RDI-C-P, RDI-P-P, LOM-P, REI-P,
B3-BIP-P
Alarm History
Alarm History
SDH/SONET
Line Alarm
SONET
VT-Path
LOP-V, AIS-V, SD-V, SF-V, UNEQ-V, PLM-V, TIM-V,
RDI-P-V, RDI-S-V, RDI-C-V, REI-V, BIP-V
Alarm Queue
Contains up to 300 alarm records of latest alarm types, alarm severity, date, and time.
Electrical
DC Power
-48Vdc (-36 to -72 Vdc)
Power consumption
240 Watts
Physical and Environmental
Dimensions for 6U
433mm x264mm x 223.5mm (W/H/D)
Temperature
0 to 50°C
Humidity
0-95%RH (non-condensing)
Mounting Desk-top
stackable, 19/23 inch rack mountable, and wall mountable
Certifications
EMI/EMC
EN55022 Class A, EN55024
FCC Part 15 Class A,
Safety
IEC60950-1, IEC 61850-3, IEEE 1613
Note for IEC 61850-3 and IEEE1613:
(1) The certification only applies to O9500-R with 48Vdc/150W power module
(2) The magento card does not support IEC 61850-3 and IEEE 1613
(3) Use shielding cable with the following modules:
z
RS232-X.50 module
z
DTE of Conference module
z
Input Port of Dry Contact module
z
RS232 X.50-8 module
z
V.35 module
z
V.36/RS449/EIA530 module
z
Input Port of Dry Contact B module
z
X.21 module
z
SNMP of XCU
z
Console port of XCU