7. Service and Maintenance
7.1.3 Calibrating the Vaporizer
Since all vaporizers have different electrical qualities, the
Tiny FX
must be recalibrated
after every exchange of the vaporizer.
IMPORTANT
: During the calibration process the vaporizer temperature must be at
70° F. Never start fogging before the calibrating process. Too cold or too warm units
must first adapt to the room temperature (70° F).
a) Connect the battery-pack to the machine.
Please note
: Do
not
switch on the machine by pressing the start button in the ma-
chines lid. If the LED is flashing wait until the machine switches off and the LED stop
flashing (approx. 1 minute).
b) Press the calibration button at the back of the machine with a small screwdriver or
something similar.
The calibrating process now starts automatically. The yellow LED [5] flashes six times
with a short pause after the second and the fourth flash to confirm the calibrati-
on.
c) The calibration process is now complete.