8. Service and Maintenance
8.3 Care and Maintenance
To ensure perfect performance of the
Tiny F07
, you should consider the following
notes:
– Make sure the fluid bottle as well as the connecting spout and the quick
connector are clean and free from small bits of dirt.
– Clean the unit from time to time, especially if you use it in a built-in state/
condition. Unscrew the unit with a suitable screwdriver (No. 1 Phillips) and
wipe it out carefully using a dry, fluff-free cloth.
– Should the vaporizer become clogged, please change it in the way as described
in section 8.1.
– If the
Tiny F07
isn‘t in use for a longer time, please take care that the fluid
tube is emptied. It could be that some fluid drops come out of the nozzle and
the surrounding gets wet and greasy.
– The battery should be charged before storing.
a) Disconnect the machine from the battery-pack.
b) Remove the new vaporizer as explained in point 8.1.1.
c) Connect the
Tiny F07
to the battery-pack and press the start button in the
machines lid [4] once.
d) Disconnect the
Tiny F07
from the battery-pack.
e) Install the new vaporizer again and calibrate it as explained in point 8.1.3.
8.2.3 The new vaporizer cannot be calibrated
(no confirmation of the process by the LED)