TigWeld 200EX 200amp AC/DC
TIG Welder
~ 15 ~
PF Pulse frequency
Unit Hz
Setting range 0.5
—
200
Factory setting 0.5
Important!
Only selectable when “pulse key” has been pressed.
DS Downslope time
Unit Seconds
Setting range 0
—
10
Factory setting 0
AC Arc current (only with 4T)
Unit Seconds
Setting range 5
—
100% of main current WC (DC)
;
10
—
100% of main current WC (AC)
Factory setting 5
PF Gas post-flow time
Unit Seconds
Setting range 0.1
—
10
Factory setting 3
AC frequency (only with TIG-AC)
Unit Hz
Setting range 50
—
250 (WC<50A)
50
—
200 (50A
≤
WC<100A)
50
—
150 (100A
≤
WC<150A)
50
—
100 (150A
≤
WC<200A)
Balance (only with TIG-AC)
Balance adjustment is mainly used to set the adjustment of eliminating metal-oxide (such as
Aluminium, Magnesium and its alloy) while in AC output mode.
Unit %
Setting range 15
—
50
Factory setting 15
(9) Rod electrode (Stick) welding key
Parameter Setting range
Arc force
0-10
Hot start
0-10
Arc length
0-10