(8) Adjusting dial
If the parameter indicator lights up, then the selected parameter can be altered on adjusting dial.
Available parameters where 2T and 4T mode have been selected:
PF Gas pre-flow time
Unit Seconds
Setting range 0.1
—
1
Factory setting 0.3
SA Starting current (only with 4T)
Unit Amps
Setting range 5
—
100% of main current WC (DC)
;
10
—
100%of main current WC (A/C)
Factory setting 5
UPS Upslope time
Unit Seconds
Setting range 0
—
10
Factory setting 0
WC Welding current
Unit Amps
5
—
200 (TIG-DC)
;
10
—
200 (TIG-AC)
;
5
—
170 (Stick-DC)
;
10
—
170 (Stick-AC)
BC Base current
Unit Amps
5
—
200 (DC)
;
10
—
200 (AC)
Important!
Only selectable when “pulse key” has been pressed.
PW Pulse Width
Unit %
Setting range 5
—
100
Factory setting 5
Important!
Only selectable when “pulse key” has been pressed.
PF
SA
UPS
WC
AC
PF
DS
PF
PW
BC
WC