Paging Groups
1. Enter the number for the pager or the group.
• If only paging staff pagers and have the transmitter default set to Pager, enter the pager or group
number directly.
• If paging, default is set to Guest, press Staff before entering the pager or group number.
2. Enter the message to send.
3. Press ENTER.
To Turn Group Paging On/Off
1. Press SETUP and enter the Password.
2. Press 1 (System).
3. Press F2 (DN) until display shows 2) POCSAG.
4. Press 1) Groups Enabled.
5. Select 2) Group Paging.
6. Press F1 (Yes) or F4 (No).
Dry Contacts
The Dry Contact are contacts or switches that are connected through a wire to the T7460, for example: Door-
bell. This sensor can send a message to the pager when an event occurs (e.g., alarms if a door is opened).
Default setting for the Contact Sensor is OFF. To program the Contact Sensor (Dry Contact):
1. Press SETUP and enter the Password.
2. Press F2 (DN) until the display shows 1: Dry Contact.
3. Select 1 (1: Dry Contact).
4. At the Contact Menu screen - select 1 (1: Prog Contacts).
5. Select contact to program - press 1 (1: Contact #1) or 2 (2: Contact #2).
6. The Screen will show if Contact Sensor is currently on or off:
• Press F1 to turn the function ON.
• Press F2 to turn the function OFF.
7. If select ON, select for the sensor to set as:
• Press F4 for Normally Closed (this is the default setting).
• Press F1 for Normally Open.
8. Enter the pager number that will be pager when this event occurs (Pager Num = - - - - ) and press ENTER.
9. Enter a User Message:
• Press F2 to create a new message, use the 1-9 keys to
enter the text, and then press ENTER to Save.
• Press F1 to edit the current message.
10. Select paging type mode - F1 (STAFF), F4 (GUEST).
11. Press F4 to EXIT.
Long Range Systems
12
Freedom User Manual
Dry Contacts
Power
USB
Ethernet
Antenna
T7460 Back View