background image

Operation and Maintenance Instruction LNK-OM-LB-02B/V3.4

 

 

Figure 3-3 

SECTION 

  S

TORAGE

 R

EQUIREMENTS

 

4.1      Storage Environment Requirements

 

LNK-LB-02B lifebuoy light should be stored in a clean, non-pollution and liquid free environment. 

4.2      Storage Temperature and Humidity Requirements

 

Storage temperature should be within -

30℃

+65℃(

-22°F

+149°F)and the environment 

humidity should be less than 80%. 

SECTION 

  S

ERVICE

 L

IFE 

&

 

S

AFETY

 

            5.1    The service life of LNK-LB-02B lifebuoy light is five years from the date of manufacture. 

During the service time the storage and application conditions should meet the Section 

storage 

requirements. 

            5.2    Once the light was been activated ,it can keep working for more than 2.0cd light intensity 

during at least 24 hours (10 hours at -1

).   

            5.3    The users are suggested to replace new batteries for the light, when the

 

accumulative 

working time is more than 10 hours. After replacing batteries, the light can be put back into 
service if it was less than 5 years from the date of manufacture. 

            5.4    LNK-LB-02B lifebuoy light contains batteries. These processes must be handled correctly: 

5.4.1 Do not dismantle battery pack; 

              5.4.2 Do not make any external electrical connection; 

              5.4.3 Do not recharge; 

              5.4.4 Do not incinerate; 

              5.4.5 Store between -30

+65

SECTION 

  I

NSPECTION

 

6.1    Inspection Time

 

LNK-LB-02B lifebuoy light should be inspected before installation or regularly inspected annually 

after installation.   

6.2    Inspection Methods

 

6.2.1    Inspect light for signs of damage or corrosion. The service life of light body except battery 

is 5years from the manufacturing date. But if there is any damage of it, the light should be 
removed and replaced by a new one. 

6.2.2    Examine the expiry date, if the light is expired, it should be removed and replaced by a 

Summary of Contents for LNK-LB-02B

Page 1: ...m Add N307 Weiye Building China Pioneering Park Xiamen Fujian361009 P R China OPERATION and MAINTENANCE INSTRUCTIONS Product Name Lifebuoy Light Product Type LNK LB 02B Document No LNK OM LB 02B Version V3 4 Total Pages 7 pages in all Effective Date December 30 2018 Revision Date April 8 2020 ...

Page 2: ...SECTION ⅡDESCRIPTION 2 SECTION Ⅲ INSTALLATION ASSEMBLE INSTRUCTIONS 4 SECTION Ⅳ STORAGE REQUIREMENTS 6 SECTION Ⅴ SERVICE LIFE SAFETY 6 SECTION Ⅵ INSPECTION 6 SECTION Ⅶ MAINTENANCE 7 SECTION Ⅷ REPAIR AND DISPOSAL INSTRUCTIONS 7 SECTION Ⅸ PACKAGING INFORMATION 7 SECTION Ⅹ MANUFACTURER INFORMATION 7 ...

Page 3: ...ter and the LED lamp end automatic upwards Then the light will be activated automatic ally and keep outputting the flashing white light more than 2 0cd light intensity during at least 24 hours 10hrs at 1 which can uninterruptedly indicate the position of lifebuoy to increase the success rate of rescue The light was designed with gravity sensor activation system It would automatically turn off once...

Page 4: ...Dimension Main body Φ60 144mm Activation Automatically turn on when the head of light is upwards Automatically turn off when the head of light is downwards Performance Fire resistant Oil resistant Mould proof Corrosion proof Water proof Resistance UV Environment Performance Meet RoHS and asbestos free requirements Standards MSC 81 70 as amended Certifications MED Table 2 1 Technical parameter 2 4M...

Page 5: ...he clip is normally installed by the side of lifebuoy and the lifebuoy light placed on the clip meanwhile it must tied together with the lifebuoy firmly with the rope The typical installation is shown as below Figure3 2 Users must ensure that the light can be pulled out from the clip and go with the lifebuoy it attached with when the lifebuoy is thrown into water 3 2 1 Twist the light and turn the...

Page 6: ...s below steps 3 3 1 The first step is remove the light from install clip and unscrew the light 3 3 2 The second step is remove the used batteries and replace with 2pcs new AA alkaline battery The battery s negative pole must towards battery case and positive pole towards LED lamp as Figure 3 3 shows 3 3 3 The third step is screw the head of light back to battery case Users must ensure the rubber s...

Page 7: ...uggested to replace new batteries for the light when the accumulative working time is more than 10 hours After replacing batteries the light can be put back into service if it was less than 5 years from the date of manufacture 5 4 LNK LB 02B lifebuoy light contains batteries These processes must be handled correctly 5 4 1 Do not dismantle battery pack 5 4 2 Do not make any external electrical conn...

Page 8: ... downwards all the time SECTION Ⅷ REPAIR AND DISPOSAL INSTRUCTIONS 8 1 Repair Instructions LNK L B 02B lifebuoy light cannot be repaired Just dispose the used and expired lights or other defective lights and replace with new one 8 2 Disposal Instructions Dispose of used and expired lights in accordance with local regulation This process should be done through an approved environment disposal agent...

Reviews: