![Lombardini LGA 280 OHC Workshop Manual Download Page 38](http://html.mh-extra.com/html/lombardini/lga-280-ohc/lga-280-ohc_workshop-manual_1938357038.webp)
REG. CODE
1-5302-528
MODEL N°
50805
DATE OF ISSUE
31.07.2001
REVISION
00
DATE
31.07.2001
ENDORSED
COMPILER TECO/ATL
38
STORAGE
XII
STORAGE
TEMPORARY INACTIVITY
lf the engine has to remain temporarily unused, it is advised to carry out
the following operations:
- allow the engine to turn over for ten minutes, drain off the oil from the
crankcase when the engine is hot (fig 60);
- replace the oil drain plug and fill up with new oil (fig.61) of the type
described on page 15;
- empty the fuel tank by removing the feed pipe and empty the carburetor
using the drain button, positioned under the carburetor bowl;
- clean the fins on the cylinder and head;
- remove the spark plug and pour-in a spoonful of engine oil, allow the
engine to turn over in order to distribute the oil on the cylinder, then replace
the spark plug;
- close the exhaust and intake holes of the air filter using adhesive tape;
- cover the engine and store in a dry place (fig. 62).
PREPARATION FOR STARTING
- Remove the protection and the adhesive tape from the air filter exhaust;
- clean the main and idle jets;
- for starting, follow the instructions noted in the use and maintenance
manual that is provided with all engines.
60
61
62