![Lombardini LGA 280 OHC Workshop Manual Download Page 14](http://html.mh-extra.com/html/lombardini/lga-280-ohc/lga-280-ohc_workshop-manual_1938357014.webp)
REG. CODE
1-5302-528
MODEL N°
50805
DATE OF ISSUE
31.07.2001
REVISION
00
DATE
31.07.2001
ENDORSED
COMPILER TECO/ATL
14
MAINTENANCE - RECOMMENDED OIL - FUELS AND LUBRICANTS
VII
10 20 25 50 100 300 500 1000 2500
MAINTENANCE
CLEANING
INSPECTION
REPLACEMENT
INTERVAL (HOURS)
COMPONENT
OPERATION
Air filter cartridge
Fuel filter
Cylinder and head fins
Oil level in housing
Distance of glow plug electrodes
Valve play
Timing belt
Oil in housing
Paper cartridge of air filter
Timing belt
•
•
•
•
•
•
•
•
•
•
Failure to carry out the operations described in the table may lead to technical damage to the machine
and/or system
To avoid explosions or fire outbreaks, do not smoke or use naked flames during the operations.
Fuel vapours are highly toxic. Only carry out the operations outdoors or in a well-ventilated place.
Keep your face well away from the plug to prevent harmful vapours from being inhaled. Dispose of fuel in the
correct way and do not litter as it is highly polluting.
FUEL
When refuelling, it is advisable to use a funnel to prevent fuel from spilling out. The fuel should also be filtered to
prevent dust or dirt from entering the tank.
Use PREMIUM gasoline or UNLEADED PREMIUM gasoline of the type used in cars. Use of other types of fuel could
damage the engine.
The octane rating of the fuel must be higher than 95 to prevent difficult starting.
Do not use old, dirty gasoline or oil-gasoline, water-gasoline mixtures since this would cause serious engine faults.
The tank capacity is:
6 l.