8 2
18-10-2004
18-10-2004
00
REG. CODE
1-5302-662
MODEL N°
51092
DATE OF ISSUE
REVISION
DATE
ENDORSED
COMPILER TECO/ATI
XI
DISASSEMBLY/REASSEMBLY
Main features of electrical starter .
Type
BOSCH
STARTER MOTOR PERFORMANCE
Rated voltage
12V
NO LOAD
LOAD
LOCK
Rated output
1,6 kW
VOLTAGE
12V
9V
6V
Direction of rotation
Sinistra
CURRENT
max 75A
390A
max 780A
TORQUE
----
MIN 1 Kgm
MIN 2,2 Kgm
REVOLUTION
MIN 8.000 g/1'
MIN 1.500 g/1'
----
Connection with engine.
Starting motor
4-pole permanent-magnet-type starting motor.
It is controlled by a remote control allowing pinion clutch and power supply enabling.
The starting motor is battery powered and controlled by a key switch.
It is connected to the engine by means of the pinion and of the ring gear on the flywheel.
Solenoid starter characteristics
Contact closing voltage at ........................ 20° C
≤
7,8 V
Contact closing voltage at ........................ 100° C
≤
10,3 V
Contact release max voltage ....................
≤
5 V
1. Starting winding
2. Running winding
ELECTRICAL DIAGRAM