Configuration and Set up Information
Module 7026
5-44
Figure 4 Locus plot of X against R for the block of cheese
Product Compensation
These so called locus plots can give us a valuable understanding of how the
metal detector works, and how it must be set up for optimum performance in
different applications. Consider Figure 5, which shows the locus plot both for a
tub of frozen ice cream and a 2mm Ferrous sample. In this example, if the
control unit is set to look at the R signal only, then when the R signal increases it
must be due to contamination, as the ice cream gives little R signal.
Figure 5 Locus plots for Ice cream tub and 2mm ferrous sample
X
R
X
R
2mm Fe
Ice cream
Summary of Contents for IQ2
Page 92: ...Maintenance Module 8023 6 1 Frequency links Tx Inductors Balance inductors ...
Page 101: ...Wiring Diagrams Module 10088 8 2 Figure 1 Optional External Sensor Connection Ladder Diagram ...
Page 102: ...Spare Parts Module 11050 9 1 SPARE PARTS CONTENTS Spare Parts Lists 2 ...
Page 104: ...Service Return Module 12005 8 1 SERVICE RETURNS FORMS CONTENTS Instructions 2 Form 3 ...