Configuration and Set up Information
Module 7026
5-38
Operating conditions:
The
Tracking limits
menu is only available if
Tracker
has been set to
ON
in the
User
options
menu. For this option to be available, a photo-eye must be fitted for product
registration purposes.
Tracking is product relative, i.e. the function can be turned on or off for each of the 100
product memories each memory can contain unique settings.
Tracker initialisation will occur whenever:
The detector is powered on:
The running product is changed.
The
Tracking limits
parameters are changed.
Upon completion of the product calibration routine the derived working threshold will be
used unless the product signal initiates a change.
The following table describes the Tracking menu:
Menu
Description
Advice
*Tracking
Turns the tracker
option on or off.
Can be set on a per product basis.
*Min limit
Lowest tracking limit.
Commences at the calibrated working
threshold.
The value cannot be set less than the
calibrated working threshold but may be
increased up to the value of the Max limit.
*Max limit
Highest tracking limit.
Commences at twice the calibrated
working threshold. The value cannot be
set less than the calibrated working
threshold but may be increased up to the
value of your choice. However it is
strongly advised to set this value to just
greater than the typical amount by which
the product signal is expected to change.
All signals that exceed this value will be
rejected.
*Max limit
Maximum limit value
lock/unlock
Once the highest tracking limit value has
been entered the value can be locked to
prevent a change should a re-calibration
occur.
*Adjustment
Factor by which the
threshold changes.
The factor range is 0 - 9 where 9 is the
largest. The default value is 1.
*Number of
packs
Number of packs
included in the tracker
calculations
The rolling pack number included within
the tracker calculations. The range is 1 -
100 where 100 is the finest control. The
default value is 10.
Summary of Contents for IQ2
Page 92: ...Maintenance Module 8023 6 1 Frequency links Tx Inductors Balance inductors ...
Page 101: ...Wiring Diagrams Module 10088 8 2 Figure 1 Optional External Sensor Connection Ladder Diagram ...
Page 102: ...Spare Parts Module 11050 9 1 SPARE PARTS CONTENTS Spare Parts Lists 2 ...
Page 104: ...Service Return Module 12005 8 1 SERVICE RETURNS FORMS CONTENTS Instructions 2 Form 3 ...