OM-LKS-45G 9
ElECTRICAllY gROUNd ThE UNIT AT ThE
TERmINAl PROvIdEd. FAIlURE TO gROUNd
ThE UNIT COUld RESUlT IN ElECTROCUTION
ANd dEATh.
dO NOT CONNECT ANY PIPINg TO ThE POP
SAFETY vAlvE. ThE vAlvE mUST bE FREE
TO vENT STEAm AS NEEdEd. ImPROPER
INSTAllATION wIll vOId ThE wARRANTY!
•
Turn the black plastic handle clockwise to seal off the tangent valve. Turn
it counter-clockwise to open the valve. The valve should open and close
easily, without binding or major effort; and seal completely when closed.
3.
Install OPTIONAl Tangent drain Strainer (If Ordered):
The LoLo LKS-45G Kettle can be ordered with tangent drain strainers that are
designed to keep food solids (cut carrots, potatoes, peas, etc.) from collecting in
and blocking the tangent drawoff valve. A drain strainer will allow liquids (stock,
etc.) to drain, while holding back food solids.
Three different optional Drain Strainers are available: a Solid Disk Strainer, a ¼”
(6 mm) Perforated Disk Strainer and a 1/8” (3 mm) Perforated Disk Strainer. To
install any of the three:
•
Remove Disk Strainer from protective packaging.
•
Position the heavy wire clip under the shield-shaped strainer, reach into
the kettle vessel interior and insert the centering clip into the tangent
drawoff tube opening.
•
Center the shield-shaped strainer over the tangent opening, tight against
the kettle bottom.
4.
For OPTIONAl Flanged Feet:
•
Obtain sufficient help or use material handling equipment to lift one side of
the kettle.
•
Use a heavy screwdriver and hammer (or mallet) to tap the adjustable
bullet feet out of the frame support legs. They are a tight press fit.
•
Position the optional flanged foot into the frame support leg and use the
hammer or mallet to seat the flanged foot. Don’t bend the floor flange
when seating the foot.
NOTE
: Flanged feet are height adjustable and can be leveled by following the
Kettle Leveling Instructions on page 8. After the Kettle is positioned as desired
and leveled, the flanged feet can be secured with floor anchors, per local codes
and best practice.
mAKE ElECTRIC POwER CONNECTION
1. Provide 120 VAC, 60 Hz, 1 Ph, 15 Amp electrical service for standard unit. Use
1/2 inch waterproof conduit and waterproof connections. A cutout is provided in
the back of the control panel enclosure, just above the gas pipe nipple.
ImPORTANT
: Observe local codes and/or The National Electrical Code in
accordance with ANSI/NFPA-70 latest edition. In Canada, provide electrical
service in accordance with the Canadian Electrical Code CSA C22.1 Part 1 and/
or local codes.
2. AN ELECTRICAL GROUND IS REQUIRED. The electrical schematic is located on
the inside of the service panel, and on page 25 of this manual.
Installation Instructions