Technical information 

Weight 

15 kg 

Width 

33 cm 

Lenght 

104 cm 

Height 

47 cm 

SWL 

160 kg 

Type plate (Figure 10) identifies the product. Please have model and serial number available when ordering spare 
parts. 

 

 

 

 

 

 

 

 

 

8.1

 

Standards 

LOJER 19100 Pulley, 19200 Speed Pulley and 19300 Vertical Pull are in conformity with the following essential 
requirements of the Directive 93/42/EEC (Medical Devices) and the corresponding Finnish National Law no. 629 
(2010). The designing of these devices is based on the following harmonized standards: 

IEC 62366:2007,  

EN ISO 14971:2009,  

Quality Management System: ISO 9001:2000 

The products are marked with the CE marking. 

9

 

Troubleshooting 

Please have following information ready before calling the service: 

 

Product name and model 

 

Serial number 

 

Year if purchase 

 

Detailed description of the problem 

 

 

 

 

 

 

 

 

 

Figure 10: Type plate and its location 

 

Summary of Contents for 2174088

Page 1: ...Lojer 3 section bench Operating instructions 18 06 2012 1 0 Art Nr 2174088...

Page 2: ...tion 5 4 2 Warnings 6 5 Functions and adjustments 7 5 1 Angle adjustment of the different sections 7 5 2 Lenght adjustment 7 5 3 Neck support accessory 7 5 4 Shoulder rotation trainer accessory 8 6 Cl...

Page 3: ...ing and using the device Use the device only as described and for the specified applications Store these instructions in an appropriate way making sure that the instructions are available to all possi...

Page 4: ...elivery Company and supplier about any transit damage within two 2 days of receiving the goods Ensure that the delivery contains all parts detailed in the delivery note If there is anything missing fr...

Page 5: ...e package should include all parts seen below Figure 4 Place parts 2 and 3 on according to the figure below Figure 5 Attach the parts to the bench with a bolt and nut Figure 4 Parts included in the pa...

Page 6: ...e Do not use the device if the component is found worn or damaged Keep body and clothing free and clear of all moving parts Failure to do so could result in personal injury Do not modify the structure...

Page 7: ...the structure while adjusting the table 5 2 Lenght adjustment The adjustment of the length of the middle section when pulling the yellow knob Figure 1 2 under the section you re able to adjust the le...

Page 8: ...that the screws are properly tightened Do not use the device with out instructions and supervision of the healthcare professional 6 Cleaning Clean the different sections of the device with a moist clo...

Page 9: ...ing essential requirements of the Directive 93 42 EEC Medical Devices and the corresponding Finnish National Law no 629 2010 The designing of these devices is based on the following harmonized standar...

Page 10: ...OJER s obligations are limited to the repair or at its discretion replacement of the product or the defective part Defective parts shall be replaced with new or as good as new parts If necessary the e...

Page 11: ...and insurance costs shall be borne by the customer LOJER shall assume the costs for the materials spare parts and the labour costs as required as well as the standard return transportation to the send...

Page 12: ...2 Email info lojer com www lojer com Record your product data here Model number ________________________________________________________ Device purchase date __________________________________________...