Display Overview
UTRED30-16 User Guide
22
battery needs to be changed by a qualified technician.
Main Battery Condition
A battery test is performed periodically. Depending on the condition of the battery, all, some or
none of the 4 bars will show. See
Powering the UTRED30-16 on page 24
ALARM/OK indicator
The symbol is shown as soon as the UTRED30-16 has registered an alarm event. While there are
no alarms, or if a previous alarm has been cleared, the symbol is shown.
Recording indicators
The recording indicators show what the UTRED30-16 is currently recording.
l
If
READY
is shown, the UTRED30-16 is ready to be started with the
START
/CLEAR/STOP
button.
Depending on the configuration it may already record pre-start readings.
l
If
STARTING
is shown, the logger has been started, and a start delay is active. The word
DELAY
is also shown, together with the time in hours and minutes until the start.
l
If
is shown, the UTRED30-16 is recording temperature at the sample interval defined
during configuration.
l
If
is shown together with the word
PAUSED
, the product is also recording, but the
recorded values are not taken into account when calculating alarm events and durations.
l
If the word
STOPPED
is shown, the UTRED30-16 has finished recording temperature data.
Time Value and Time Indicators
The time value display is used to show one of the following:
l
The current time
l
The time remaining until the logger starts recording (for a delayed start)
l
A duration, for example of an alarm
The time indicators identify which of those is displayed as follows:
l
If
TIME
is shown, the time value represents the current time in hours and minutes (24- hour
format).
l
If
DELAY
is shown, the time value represents a start delay, or the time remaining until a
date/time start will occur.
l
If
DURATION
is shown, the time value represents the duration, for example the time above
the upper alarm limit.
The word
boot
appears in place of the clock if new firmware is being uploaded to the UTRED30-16.
The word
dtst
appears in place of a time value if the logger is configured for a date/time start, and
the start time has not yet passed.
Reading Type
The word
CURRENT
is shown when the temperature on the display represents the last recorded
temperature.
The word
MAX
is shown in Review mode, when the temperature on the display represents the
maximum recorded temperature for the day displayed.