5.0 There must be a current supply...
5.1 Fuses - replacement
There are five fuses in the electrical circuit.
100 Amp fuse in the main supply from battery
10 Amp fuse in the control current circuit
20 Amp fuse (plug for extra equipment on the instrument board)
20 Amp fuse for built-in charger
40 Amp fuse for Rotator
Replacement:
The old fuse is to be removed and replaced by a new one of the same size.
Find out why the fuses blow!
Many operational disturbances are caused by bad
connections in the elctrical circuit. Make sure that the
connections are in order.
Check connections regularly for damage at insulating caps or
bad connections at plugs etc. Verdigris must be removed from
cable plugs. Keep all screw/nut connections tight.