Logitek mixIT Audio Console System/JET67 Manual
26
Cough – enter the GPI input where when closed will turn on the cough mute.
GPI Outputs
(valid numbers are 1-8)
Audio Start – enter the GPI output where we will pulse the relay when the fader is
turned on
Audio Stop – enter the GPI output where we will pulse the relay when the fader is
turned off
Audio Tally – enter the GPI output where we will latch the relay when the fader is on
Mute Group – enter the mute group that this microphone will belong to, where the first
mic on mutes the monitors and turns on the mute tally as defined in Control Settings, and the
last mic off un-mutes the monitors and turns off the mute tally as defined in Control Settings.
Tip: as with the local inputs, put the on air light for the studio in the Mute Tally
on the Control Settings page so it follows all of the mics in the mute group.
Use the Audio Tally for things that follow just this one source, such as a LED
glow ring for a single microphone.
UDP Control
To have the JET67 send ASCII text via UDP for device control enter the following:
UDP Port Number: a valid port number
UDP IP Address: the IP address of the device to which we are sending the text string
Start String: the text to send when the fader turns on
Stop String: the text to send when the fader turns off
The following checkboxes are relevant to the mixIT:
Fader Start: if set to yes, turn the channel on when the fader is raised from zero and off when
the fader is returned to zero.
Cue at Inf: If set to yes, put the fader in cue when the fader is returned to zero
Click Upload to JetStream to save your work.
Click Cancel Edit Changes to exit
If you click Delete this input from network, you will remove it from the list of sources in the
system, but it will return the next time the stream is announced by the sending device.